Hicom 150 E Office Rel.1.0 Service Manual - 3.3 Peripheral boards
Technical connection requirements
Max supply current approx. 34 mA, supply voltage approx. 40 V DC
Ring voltage against negative supply voltage (a-wire/RING) for max. two telephones
Range approx. 2 x 750ohms (overall resistance)
Loop detection > 10 mA
Earthing key detection > 20 mA
The transmission settings (see
the relevant
country

3.3.3 SLMC8

Introduction
The SLMC8 (subscriber line module cordless) board allows a maximum of eight base stations to be
connected to Hicom 150 E OfficePro (this configuration allows a maximum of 32 simultaneous
connections of the active subscriber).
The SLMC8 has a unique ID and may only be used once to equip a Hicom 150 E OfficePro
system with
Inserting the SLMC8 releases 16 mobile units for use (PIN numbers are assigned). These
mobile units can then be logged on to the system. Any additional mobile units to be used
must be released first.
Base stations must be clocked with a high degree of accuracy as a prerequisite for Hicom cordless 150
E operation. The
CGM
Switches and LEDs
Figure 3-16 SLMC8 (S30810-Q2911-X)
LED states and their meaning
Red LED Green LED
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (5 of 46) [06/04/2000 13:03:52]
Section
code.
Hicom cordless 150
plug-in type module on the

Table 3-14 SLMC8 - LED states

2.6.1) are configured on a country-specific basis using
E.
CBMOD
board must be used for this purpose.
State
Action