Hicom 150 E Office Rel.1.0 Service Manual - 12 Cordless Multicell Integration CMI
10x2x0,8 ST III BD 1PPERF 330 m
A-2Y(L)2Y
A-2YF(L)2Y
10x2x0,8 ST III BD
A-2Y0F(L)2Y
10x2x0,8 ST III BD
A-2Y(L)2Y...x2x0,4 *
A-2YF(L)2Y...x2x0,4 ST III BD *
A-PM...x2x0,6 ST III LG oder BD *
A-PM...x2x0,8 ST III LG *
DECT standard
Number of channels 120 duplex channels, freely administered
Frequency range
Channel spacing
Bit rate
Voice coding
Output power

12.9.2 Base station data

Base station
Antennae
Range
Measurements
Weight
Operating temperature 0 °C to +45 °C
Power supply
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_12.htm (40 of 45) [06/04/2000 13:05:57]
* Not to be used for new installations
(10 carriers each with 12 time division multiplex channels)
In Hicom cordless 150 E Version 1, only 6 time division multiplex channels
are used per carrier.
1880,928 MHz to 1898,208 MHz
(transmission and receive range)
1,728 MHz
1,152 Mbit/s
32-kbit ADPCM
10 mW (average power)
Two antennae are implemented in the housing of the base station. The base
station works with antenna diversity (this selection switch connects the radio
receiver in each case with the antenna with the greater field strength)
Fundamentally dependent on the radio transmission qualities of the
environment as well as the building
Outdoors: up to 300 m (see
Indoors: up to 50 m (see
175 x 182 x 35 (H x W x D in mm)
250 g
315 m
315 m
330 m
315 m
360 m
360 m