3.3.13 TS2

Introduction
The TS2 board (trunk module S2M) for OfficeCom allows you to connect the system to an NT1
(network transfer point) via a symmetrical line (4-wire twisted-pair cable) or a coaxial line (BNC
sockets X3 and X4) for the simultaneous transfer of up to 30 B channels (voice channels).
The total transmission speed including signalling and synchronisation is 2,048 Mbit/s.
Only one TS2 board allowed (a primary multiplex access)
For slots 6, 7, 8, or 9 only (EXTEB board required)
The max. cable length depends on the quality of the cable type used and its signal attenuation
(max. 6 dB).
Use shielded cables only to guarantee problem-free operation.
Interfaces
Figure 3-44 TS2 interfaces (S30810-Q2913-X)
Symmetrical line (120 ohms)
The 120 ohm-variant is preset in the factory (jumper setting, see table). The shielded cable is
connected to the X2 connector via an 8-speed Wieland terminal.
Table 3-33 TS2 contact
assignment for symmetrical lines
Contact
1
-48V (NT1 feeding)
2
GNDA (NT1 feeding)
3
GND shield
4
GND shield
5
Transmitter a-wire
6
Transmitter b-wire
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (41 of 46) [06/04/2000 13:03:55]