1B-36 AIR CONDITIONING (OPTIONAL)

Rear Blower Motor Switch

1. Rear blower motor switch
2. Bulb
3. Bracket
4. Rear A/C air louver case
b
a
e
d
2
3
1
5. Rear A/C air louver holder
Install proper direction as shown in figure
6. Rear A/C air louver
7. Knob
INSPECTION
• Check rear blower motor switch for each terminal-to-terminal
c
• Check rear blower motor switch bulb come ON when con-
f
4
7
5
6
continuity.
If check results are not specified, replace rear blower motor
switch.
TERMINAL
POSITION
OFF
Low
Middle
High
nect battery positive (+) cable to terminal "c" and battery
negative (–) cable to terminal "f".