C H A P T E R 5 24-Port Channelized E1/T1 Line Card Configuration - Cisco 10000 Series Configuration Manual

Router line card
Hide thumbs Also See for 10000 Series:
Table of Contents

Advertisement

Commands and Default Values
Checking Hardware and Software Compatibility
The PRE installed in the Cisco 10000 series router chassis must support the Cisco IOS software running
on the router. Use the show version command to check the PRE version installed.
To see if a feature is supported by a Cisco IOS release, to locate the software document for that feature,
or to check the minimum software requirements of Cisco IOS software with the hardware installed on
your router, Cisco maintains the Software Advisor tool on Cisco.com at
http://www.cisco.com/cgi-bin/Support/CompNav/Index.pl
This tool does not verify whether line cards within a system are compatible, but does provide the
minimum Cisco IOS requirements for individual hardware line cards, modules, or options.
You must be a registered user on Cisco.com to access this tool.
Commands and Default Values
You can operate all the line card ports to accept either E1 or T1 lines, but not both. Once you configure
a line card in E1 or T1 mode, you configure all ports on that line card as the same type controller. The
commands for configuring either E1 or T1 interfaces are described in the following sections.
E1 Commands
Table 5-2
also includes the commands to use to modify a default value, and indicates whether a similar value (on
the remote end of the connection) must be the same (or opposite).
Table 5-2
Command Name
Enable Commands
hw-module (reset)
show controllers
show interfaces
Configure Commands
card
hw-module
(shutdown)
controller
interface
Cisco 10000 Series Router Line Card Configuaration Guide
5-2
lists line card commands, default values, and specifies the command syntax you use. This table
E1 Line Card Commands and Default Values
Default Value
mode e1
no hw-module
Chapter 5
24-Port Channelized E1/T1 Line Card Configuration
Command Syntax
hw-module slot slot reset | subslot
slot/subslot reset
show controllers e1 slot/subslot/port
show interface serial
slot/subslot/port:channel-group {accounting
| controller | crb | description |
fair-queue | irb | mac-accounting | mpls-exp
| precedence | random-detect | rate-limit |
shape}
[no] card slot/subslot 24che1t1-1 mode {e1 |
t1}
[no] hw-module {slot slot shutdown | subslot
slot/subslot shutdown}
controller {e1 | t1} slot/subslot/port
[no] interface serial
slot/subslot/port:channel-group
Remote
Device
Setting
OL-8834-04

Advertisement

Table of Contents
loading

Table of Contents