Download Print this page
Cisco 1000 Series Manual

Cisco 1000 Series Manual

Install and upgrade internal modules and field replaceable units

Advertisement

Quick Links

Install and Upgrade Internal Modules and Field
Replaceable Units
The Cisco 1100 Series Integrated Services Routers have internal modules and field-replaceable units (FRUs)
that can be quickly and easily removed and replaced without having to send the entire router for repair.
This section describes how to install the internal modules and FRUs in the Cisco 1100 Series ISRs. The
information is contained in the following sections:
Replace the Chassis Covers for C111X and C1111x
To access the internal modules on the router, you must first remove the chassis cover. See the instructions
below on how to remove and later replace the chassis cover on the routers.
Warning
Only trained and qualified personnel should be allowed to install, replace or service this equipment. Statement
1030
Cisco 1100 Series ISRs have removable covers. Do not run the routers with the cover off. Doing so can cause
the router to overheat very quickly.
Use a number-2 Phillips screwdriver to perform the following tasks.
Replace the Chassis Covers for C111X and C1111x, on page 1
External Modules, on page 4
Install and Remove Small Form Pluggable Modules, on page 5
Install an LTE Pluggable Module, on page 6
Install and Upgrade Internal Modules and Field Replaceable Units
1

Advertisement

loading

Summary of Contents for Cisco 1000 Series

  • Page 1 Only trained and qualified personnel should be allowed to install, replace or service this equipment. Statement 1030 Cisco 1100 Series ISRs have removable covers. Do not run the routers with the cover off. Doing so can cause the router to overheat very quickly.
  • Page 2: Remove The Cover

    Install and Upgrade Internal Modules and Field Replaceable Units Remove the Cover Remove the Cover To remove the cover, do these steps: 1 and 2 Remove the 14 screws from either side of the cover. Step 1 Read the Safety Warnings and disconnect the power supply before you perform any module replacement. Step 2 Confirm the router is turned off and disconnected from the power supply.
  • Page 3: Replace The Cover

    Install and Upgrade Internal Modules and Field Replaceable Units Replace the Cover Step 3 Disconnect all port cables connected to the router. Ensure that you do not work on the router with cables still attached to the router in the event of lightning or surges. Step 4 Installer to disconnect all cables connected to the system.
  • Page 4: External Modules

    This section describes how to install external modules and FRUs in the Cisco 1100 Series ISRs. The information is contained in the following sections: Warning Only trained and qualified personnel should be allowed to install, replace or service this equipment.
  • Page 5 Install and Remove Small Form Pluggable Modules Install and Remove Small Form Pluggable Modules This section describes how to install and remove Small Form Pluggable (SFP) modules in the Cisco 1100 Series ISRs. The information is contained in the following sections: Warning Pluggable optical modules comply with IEC 60825-1 Ed.
  • Page 6 Install and Upgrade Internal Modules and Field Replaceable Units Install an LTE Pluggable Module Install an LTE Pluggable Module Warning To reduce the risk of electric shock, the chassis of this equipment needs to be connected to permanent earth ground during normal use Statement 445 Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis;...
  • Page 7 Install and Upgrade Internal Modules and Field Replaceable Units Install an LTE Pluggable Module on a C1101-4P LTE Pluggables LTE Pluggable Technology LTE CAT4 Install an LTE Pluggable Module on a C1101-4P To insert the LTE pluggable module into the router, do these steps: Step 1 Insert and then gently push the LTE pluggable into the pluggable slot of C1101-4P until firmly fixed.
  • Page 8 Install and Upgrade Internal Modules and Field Replaceable Units Install an LTE Pluggable Module on a C1101-4P Figure 2: LTE Pluggable - C1127X-8PLTEP Item Description GPS Antenna LTE Antenna Ground Lug Kensingston Lock Slot Install and Upgrade Internal Modules and Field Replaceable Units...
  • Page 9 Install and Upgrade Internal Modules and Field Replaceable Units Install an LTE Pluggable Module on a C1101-4P Figure 3: LTE Pluggable - C1118-8PLTEAP Item Description Mini-PCIE Common heat spreader + thermal interface Enclosure base to support 4-antenna 4-1 SMA-MHF4 cable assembly SMA Diversity Antenna for usability and Micro-USB port access Figure 4: LTE Pluggable - C1118-8PLTEAP Back Panel Install and Upgrade Internal Modules and Field Replaceable Units...
  • Page 10 Install and Upgrade Internal Modules and Field Replaceable Units Install an LTE Pluggable Module on a C1101-4P Figure 5: C1118-8PLTEAP with Micro SIM Slots This section describes how to insert a Micro-SIM card into an LTE pluggable module. To insert the Micro-SIM cards into an LTE Pluggable module: Note Ensure to use the correct tool for removing the Micro-SIM door.
  • Page 11 Install and Upgrade Internal Modules and Field Replaceable Units Install a Micro-SIM Card into a USB LTE Dongle Figure 6: Insert the Micro-SIM cards Install a Micro-SIM Card into a USB LTE Dongle This section describes how to insert a micro-SIM card into a USB LTE dongle in a C1101-4P router. Install and Upgrade Internal Modules and Field Replaceable Units...
  • Page 12 Install and Upgrade Internal Modules and Field Replaceable Units Install a Micro-SIM Card into a USB LTE Dongle Figure 7: Micro-SIM Card Slot with Dust Cover Step 1 To insert a micro-SIM card into a USB LTE dongle, do these steps: a.
  • Page 13 Install and Upgrade Internal Modules and Field Replaceable Units Install a Micro-SIM Card into a USB LTE Dongle Figure 8: LTE USB 2.0 Dongle for C1101-4P Number Description Supporting ring Magnet Extend outward 30mm Plug-in direction Number Description Supporting ring Dongle holder with magnet Router-C1101-4PLTEPW Install and Upgrade Internal Modules and Field Replaceable Units...
  • Page 14: Antenna Mounting Instructions

    Follow the same procedure to install the USB LTE dongle onto routers with a vertical USB slot. Antenna Mounting Instructions This section describes how to mount the antenna on Cisco 1000 Series ISRs. The information is contained in the following sections:...
  • Page 15 Install and Upgrade Internal Modules and Field Replaceable Units Option A - Rack Mount at the Same Height with the Platform Both options - A and B should follow these remaining steps to complete the mounting procedure: 1. Assemble dongle, USB, cable and antenna together in advance. 2.
  • Page 16 Install and Upgrade Internal Modules and Field Replaceable Units Wall Mount of the Antenna Wall Mount of the Antenna To install the antenna on a wall, do these steps: Step 1 Pick up the C-Bracket (700-121628-01), place the bracket and then fix it on the wall using four screws. Step 2 Assemble the USB cable (74-122795-01), dongle and antenna (07-100470-01) together.
  • Page 17 Install and Upgrade Internal Modules and Field Replaceable Units Connect the Antenna to the Device Connect the Antenna to the Device Step 1 Ensure the reserved USB cable length is sufficient to reach the device. Step 2 Ensure the use the cable clip within USB cable kit (74-122795-01) to manage cable routing and to hold the cable weight. Step 3 Ensure there are no sharp radius within the USB cable routing.
  • Page 18 Install and Upgrade Internal Modules and Field Replaceable Units Ceiling Mount of the Antenna Ceiling Mount of the Antenna To install the antenna on a rack, do these steps: Option A - Rack Mount at a Different Height with the Platform Step 1 Pick up the R-Brackets (700-121611-01) Step 2...
  • Page 19 Install and Upgrade Internal Modules and Field Replaceable Units Option A - Rack Mount at the Same Height with the Platform Option A - Rack Mount at the Same Height with the Platform Step 1 Pick up the R-Brackets (700-121611-01)Place and fix the bracket at an appropriate location on the rack using two screws. Step 2 Tighten the screw, the recommended torque is 10-12 in-lb.
  • Page 20 Install and Upgrade Internal Modules and Field Replaceable Units Option A - Rack Mount at the Same Height with the Platform Install and Upgrade Internal Modules and Field Replaceable Units...