Juniper mesa 2 Owner's Manual page 74

Hide thumbs Also See for mesa 2:
Table of Contents

Advertisement

FEATURE
Temperature
Specifications
Shock
Resistance
Environmental
Ratings and
Standards
Certifications
and Standards
Warranties
70
Mesa 2 Rugged Tablet Owner's Manual
SPECIFICATION
Operating Temperature: -4°F to 122°F
(-20°C to 50°C).
Storage Temperature: -22°F to 158°F
(-30°C to 70°C)
Battery Charging Temperature: -4°F
to 140°F (-20°C to 60°C)
Withstands multiple 4 foot drops to
concrete
IP68 rating (1.4 meters for 2 hours),
waterproof and dustproof
Designed to MIL-STD810G.
Tests:
ME-60: sand & dust
ME-51,53,& 54: X,Y,& Z-axis helicopter
vibe
ME-55, 56, & 57: X, Y, & Z -axis general
vibe
ME-52: Water Immersion, 1 meter
ME-59: Aggravated Temperature-
Humidity cycle
ME-67: Temperature cycle
ME-62: Temperature shock
ME-66: Altitude
FCC Class B
CE Marking
Industry Canada
Australia (ACMA)
IEC/EN 60950 safety
Bluetooth SIG qualification
IP68 waterproof and dustproof
Designed to MIL-STD 810G
RoHS 2 compliant
24 months for Mesa 2
90 days for accessories
Extended service and maintenance
plans