23 - 64
DOOR - FRONT
FRONT DOOR OUTSIDE HANDLE (Continued)
Fig. 3 Access Plug
1 - ACCESS PLUG
2 - DOOR
INSTALLATION
(1) Position outside handle in the door.
(2) Install nuts attaching outside door handle to
door. Tighten the nuts to 5.0 N·m (45 in. lbs) torque.
(3) Engage outside handle to latch rod to the latch.
(4) Engage lock cylinder to latch rod to the latch.
(5) Install fastener access plug in the door end
panel.
1 - OUTSIDE HANDLE
2 - LOCK CYLINDER TO LATCH ROD
3 - LOCK BUTTON TO LATCH ROD
(6) Install water dam.
(7) Install door trim panel.
FDR LOWER GLASS RUN
CHANNELS
REMOVAL
(1) Remove trim panel.
(2) Remove water dam as necessary to access
lower run channels.
(3) Remove bolts attaching lower glass run chan-
nels to door panel (Fig. 5).
(4) Remove glass.
(5) Slide lower run channels downward to disen-
gage from upper run channels.
(6) Remove lower run channels from door.
INSTALLATION
(1) Position lower run channels in door.
(2) Slide lower run channels upward to engage
into upper run channels.
(3) Install glass.
(4) Install bolts attaching lower glass run channels
to door panel.
(5) Install water dam.
(6) Install trim panel.
Fig. 4 Outside Door Handle
4 - LATCH
5 - INSIDE HANDLE TO LATCH ROD
6 - OUTSIDE HANDLE TO LATCH ROD
AN