Cancelling Forced Status For All Bits - Omron ns series Operation Manual

Ladder monitor i/o comment extracting tools
Hide thumbs Also See for ns series:
Table of Contents

Advertisement

3-7
Changing Address Status/Contents
3-7-2

Cancelling Forced Status for All Bits

3. The following Change Value Dialog Box will be displayed.
4. Select first four shown in the dialog box to set, reset, force-set, or force-reset the bit.
To cancel forced status, select Force Set/Reset Cancel.
5. Press the Update Button.
3-7-2
Cancelling Forced Status for All Bits
There are two ways to cancel forced status for all addresses, as shown below.
1. Perform either of the following operations.
• Cancel forced status from the Change Value Dialog Box.
• Cancel forced status from the Check Forced Bits Dialog Box.
Canceling Forced Status from the Change Value Dialog Box
1.
Press the Cancel All Button in the Change Value Dialog Box.
2.
A message will be displayed for confirmation. Press the OK Button.
Canceling Forced Status from the Check Forced Bits Dialog Box
Communications addresses with forced status can be displayed in a list in the Check
Forced Bits Dialog Box, and they can be cleared in a batch. It is possible to display the
Check Forced Bits Dialog Box when starting or stopping the Ladder Monitor, to check
forced status before starting the Ladder Monitor or to check that the Ladder Monitor is not
being stopped without proper preparation.
1.
Select Check Forced Bits from the menu that is displayed by pressing the Menu
Button.