Using The I/O Comment Extracting Tool - Omron ns series Operation Manual

Ladder monitor i/o comment extracting tools
Hide thumbs Also See for ns series:
Table of Contents

Advertisement

1-4

Using the I/O Comment Extracting Tool

1-4 Using the I/O Comment Extracting
Tool
Use the following procedure to display I/O comments on the NS-series Ladder Monitor.
1.
Install the I/O Comment Extracting Tool.
2.
Create the CXT file:
Save the project file for the connected PLC as a CXT file (extension.cxt) on CX-
Programmer.
3.
Specify the PLC from the CXT file mentioned above using I/O Comment Extracting
Tool, extract I/O comment data, and convert it to the Ladder Monitor I/O comment
file (extension.ioc).
4.
Copy the Ladder Monitor I/O comment file (extension.ioc) to the Memory Card or to
the PT.
● Using a Memory Card
1) Place the Memory Card in the PC card slot of the computer using a Memory Card
2) On the computer, copy the converted Ladder Monitor I/O comment file
3) Turn OFF the power to the PT. Place the Memory Card in the Memory Card
● Copying the File Directly to the PT
1) On the computer, copy the converted Ladder Monitor I/O comment file to the
2) Connect the computer to the PT.
3) Transfer the Ladder Monitor I/O comment file to the PT using a transfer program
5.
Turn ON the power to the PT and use one of the following methods after the PT
enters RUN mode to display the System Menu.
• NS15
8
adapter.
(extension.ioc) along with the Ladder Monitor application to the Memory Card
using Explorer or another application.
Copy the data to the ldrdata folder in a Memory Card
connector at the back of PT.
project folder for the PT using Explorer or another application.
or the CX-Designer. (Refer to Transferring Data to the PT in the CX-Designer
online help for information on the transfer program and CX-Designer.)
Press one of the four corners of the touch panel twice in a row.
Press one corner
twice in a row.