E1000011; E1000030; E1000037; E100003B - HP XP User Manual

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

See
"About errors attributable to disk array systems" (page

E1000011

Message
Device IP:[IP address] not added to the list, password protection is enabled
Explanation
Because the password protection function is enabled, registration of the disk array system failed.
Recommended action
Use Storage Management Software to confirm the valid or invalid setting of the password
protection function of the disk array system. If it is valid, change it to invalid.

E1000030

Message
Attach failed for: [device path], returns: [Error message]
Explanation
Failed to recognize the disk array system.
Recommended action
(1) Perform the following using Storage Management Software:
1) Confirm whether the serial number you specified is correct.
2) Confirm that a command device is set, and set one if not.
(2) Confirm whether it falls under a limit in the use of RAID Manager. See Table 2.5.2 -3.
(3) In case of using VMware Guest to Guest Backup (FC) function, VSS Provider may be
used from the multiple virtual machines on the same ESXi at the same time. This error is
output due to an occurrence of IO conflict between instances depending on the timing of
process request to the disk array system. To continue the process after the retry, ignore this
error after the successful backup. If the backup has failed, change "The number of VSSHP
retries" in the setup file and execute again.

E1000037

Message
Creation of S-Vol failed: The P-Vol already has an active pair.
Explanation
Failed to create S-VOL. The pair status of the LU is COPY.
Recommended action
The pair status of the specified LU is Copy.
Specify a proper LU, and re-execute.

E100003B

Message
[Port number:LUN:MU number] returns [Error message]
133).