E2002019 - HP XP User Manual

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

Explanation
Could not use the specified P-VOL for making Business Copy.
Recommended action
(1) You may have specified a P-VOL which is not targeted for a backup. Specify the correct
P-VOL.
(2)The specified P-VOL may not be mapped to the VSS installation server (application
server). Map it using Storage Management Software.
(3) Using Storage Management Software, confirm the valid/invalid setting of the Business
Copy function. If it is invalid, change it to valid.
(4) An error occurred when an operation command was given to the disk array system.
See
"About errors attributable to disk array systems" (page

E2002019

Message
S-Vol cannot be created for this volume. P-Vol is being formatted.
Explanation
Creation of S-VOL failed. P-VOL is being formatted.
Recommended action
Create the S-VOL after P-VOL formatting is complete.
E200201A
Message
Creation of S-Vol failed: The LU is already paired.
Explanation
Creation of S-VOL failed. The pair status of the LU is already PAIR
Recommended action
The pair status of the specified LU is already PAIR. Specify the correct LU and re-execute.
E200201B
Message
Operation Failed. message
Explanation
Operation Failed.
Recommended action
[XP P9500/XP7]
(1) If Host group: HP-VSS-HG does not exist, create HP-VSS-HG.
(2) Check that it does not come into conflict with the operational restrictions and points of
consideration when using RAID Manager. See Table 2.5.2-3.
(3) See the log file and provide solutions for any error messages were output.
133).
Error messages 107