HP XP User Manual page 77

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

Explanation
Pair resynchronization of P-VOL and S-VOL failed.
Recommended action
An error occurred when an operation command was given to a disk array system.
See
"About errors attributable to disk array systems" (page
5014
Type
Error
Message
Failed to restore Business Copy pair: S-VOL [LU number of S-VOL] --> P-VOL [LU number of
P-VOL], Error# [Error number]
Explanation
Restore from S-VOL to P-VOL failed.
Recommended action
An error occurred when an operation command was given to a disk array system.
See
"About errors attributable to disk array systems" (page
5017
Type
Error
Message
Failed to create V-VOL for P-VOL [LU number of P-VOL], Error# [Error number] You must use
a RAID level with redundancy for both the P-VOL and data pool as RAID 0 is not supported
Explanation
Cannot create V-VOL for P-VOL. RAID0 is not supported.
Recommended action
P-VOL of Snapshot became a RAID0 LU. Specify an LU that is not RAID0.
5019
Type
Error
Message
Failed to resync the shadow copy: Serial Number: [ serial number] Source Lun[LU number]
-->Target Luns[LU number], Error# [Error number]
Explanation
Resynchronization processing failed.
133).
133).
Error messages
77

Advertisement

Table of Contents
loading

Table of Contents