E20020Dd - HP XP User Manual

Storage adapter for microsoft volume shadowcopy
Table of Contents

Advertisement

[XP7]
In the case of the virtual DKC, create a Host group name: HP-VSS-HG in RSG which P-VOL
belongs to, and perform a similar procedure.

E20020DD

Message
Other processes are running.
Explanation
Cannot reboot because other processes are running.
Recommended action
Check the following for the same account and other user accounts of the use server.
(1) You cannot run multiple GUI tools. Closed the GUI tool and then restart it.
E20020DE
Message
Unable to get information from the device.
Explanation
Cannot get information from the disk array system.
Recommended action
[XP P9500/XP7]
(1) Reference the VSS Provider log files and other error messages, and take the
corresponding action.
(2) An error occurred when an operation command was given to the disk array system. See
"About errors attributable to disk array systems" (page
(3) Confirm whether the problem falls under the limits for using RAID Manager.
See Table 2.5.2-3.
E20020DF
Message
ResyncLuns failed. Please check the disk: [Disk Number] of destination LUN.
Explanation
Failed to ResyncLuns.
Recommended action
When a failure occurs during the restore by ResyncLuns, the P-VOL remains in offline status to
protect the consistency of the data. Set the target LUN online status from Server Manager->Disk
Management as needed.
E20020E1
Message
Resource lock failed. Serial Number: [serial number] Resource that is specified to lock has already
been used by another user.
133).
Error messages 127