Download Print this page

Life Fitness Elevation 95X-ALLXX-01 How To Do page 9

Hide thumbs Also See for Elevation 95X-ALLXX-01:

Advertisement

HOW TO... REPLACE THE USER ARM HEART RATE HAND SENSORS
Tools required: Phillips screwdriver
Estimated time required: 20 minutes
1. If the cross-trainer has
line cords, unplug them
from the wall outlets.
2. Remove the three screws
that secure the inner
and outer hand sensors
to each other.
3. Note the location of the
wires on the hand
sensors. This will
simplify reassembly.
4. Disconnect the wires.
5. Connect the wires to the
new hand sensors.
6. Install the new hand
sensors using the screws
removed and saved in
Step 3.
7. Test the new hand
sensors for proper
operation.
Heart Rate Hand
Senor (front)
Heart Rate Hand
Senor (rear)
Phillips
Screws (3)
Elevation 95X-ALLXX-01 Commercial Cross-trainer
"How To..."
35

Advertisement

loading