HOW TO... REPLACE THE GENERATOR ASSEMBLY - CONTINUED
7. Remove the previously loosened generator mounting nuts.
8. Disconnect the generator cables.
9. Remove the grommet from the mounting bracket.
The generator-bracket assembly weighs about 35 lbs. (16 kg).
10. Lift the generator/bracket
assembly out of the tower.
11. Remove and save the four
bolts that secure the
generator to the mounting
bracket.
12. Install the new generator on
the mounting bracket. Insert
the new generator cables
through the grommet before
putting the grommet in place.
13. Loosely install the new
generator-bracket assembly.
14. Place the Poly-V belt around
the generator pulley.
15. Remove the tension bolt from
the right bracket hole and
return it to the left bracket
hole.
16. Tighten the bolt until the
generator assembly returns to
its previously marked position.
17.
Tighten the generator
assembly mounting bolts.
18.
Reconnect the generator
cables.
19.
Install the remaining
components.
Elevation 95X-ALLXX-01 Commercial Cross-trainer
Generator
Washers (4)
"How To..."
Generator
Mounting Bracket
Hex Bolts (4)
63