Daikin ERQ Service Manual page 180

Erq 100/125/140 a7v1b (outdoor unit) ekeqd/f/mcbv3 (control box) ekexv 50/63/80/100/125/140 (expansion valve kit)
Hide thumbs Also See for ERQ:
Table of Contents

Advertisement

Troubleshooting by Indication on the Remote Controller
∗1: Coil check method for the moving part of the electronic expansion valve
Discount the electronic expansion valve from the PC board and check the continuity between
the connector pins.
(Normal)
1. White
2. Yellow
3. Orange
4. Blue
5. Red
6. Brown
: Continuity
×: No continuity
170
Pin No.
1. White
2. Yellow
3. Orange
4. Blue
×
Approx.
300Ω
×
Approx.
300Ω
: http://splitoff.ru/tehn-doc.html
ESIE09-05
5. Red
6. Brown
×
Approx.
150Ω
×
Approx.
150Ω
×
Approx.
150Ω
×
Approx.
150Ω