Relay Control Options and Door Lock Control
Configure PIOU, PIOUS or PEPU for Night Transfer
1.
In Program 77-1, set LED 05 to OFF to configure the Night/Hold Relay for the Night
Transfer function
2.
In Program 77-1, set LED 06 to provide continuous or pulsating relay activation:
Note
3.
Set in Programs 87, 88, and 89 the exchange lines that will activate the relay (when the
system is in the Night mode).
Assign, in Program 39, the 1LJKW 7UDQVIHU buttons to telephones that should be able
4.
to set the Strata DK40 system into the Night mode.
Assign in Programs 29-1~29-4 a 1LJKW 7UDQVIHU button on all direct station
5.
selection consoles that are to transfer the Strata DK40 system into the Night mode.
6.
If tenant operation is required, set in Program *15 the exchange lines for tenant 1
through tenant 4 operation.
7.
If using a PIOU or PEPU, set the P11 jumper plug on the PIOU or PEPU to the MAKE
or BREAK position, as required:
8.
See Figures 6-7
or PEPU to the MDF as required for the night relay function.
Note
Strata DK40 I&M Manual Spring 1999
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
(see Figures 6-7
OFF–Programs the relay for continuous activation when the 1LJKW 7UDQVIHU
button (only) is set in the Night mode.
ON–Programs the relay for pulsating activation when the 1LJKW 7UDQVIHU 4a7
button for tenant 1~4 is set to the Night mode and an Exchange line rings.
Exchange lines must be enabled in Program 78 for the Night Transfer pulsating relay
function.
MAKE–Shorts the normally open contacts (pins 9 and 34) when the night relay is
activated.
BREAK–Opens the normally closed contacts (pins 9 and 34) when the night relay is
activated.
...or
If using a PIOUS, solder the jumper W2 on the PIOUS to the MAKE or BREAK
position, as required:
MAKE–Shorts the normally open contacts (NHT and NHR) when the night relay is
activated.
BREAK–Opens the normally closed contacts (NHT and NHR) when night relay is
activated.
and
6-8
for wiring/interconnecting details. Connect the PIOU, PIOUS,
Door phones programmed to ring over external page in the Night mode do not
activate the Night Transfer feature, per Program 77-1 (See the Strata DK40
Programming Manual).
and 6-8).