FX
-64CCL User's Manual
3U
7.2.6
[BFM#27] Set value of host station number
This buffer memory address stores the set value of the host station number and is determined when the
64CCL is started.
The stored value does not change even if the setting is changed after startup.
Setting
(decimal)
1 to 64
0,65 to 99
7.2.7
[BFM#28] Number of occupied stations, expanded cyclic set value
This buffer memory address stores the value set by the rotary switch and is determined when the 64CCL is
started.
The stored value does not change even if the setting is changed after startup.
BFM#28 Number of occupation stations, expanded cyclic set value
Setting
(hexadecimal)
0
1 station
1
2 stations
2
3 stations
3
4 stations
4
1 station
5
2 stations
6
3 stations
7
4 stations
8
1 station
9
2 stations
A, B
Setting error
C
1 station
D to F
Setting error
38
BFM#27 Set value of host station number
Description
Host station number
Setting error
The set value remains stored even if a setting error occurs.
Number of occupied stations
Expanded cyclic setting
Single
Single
Single
Single
Double
Double
Double
Double
Quadruple
Quadruple
Setting error
Octuple
Setting error
7 Buffer Memory