7.

Buffer Memory

7.1

Buffer memory list

The table below provides a brief description and reference information for the 64CCL buffer memory.
BFM No.
FROM instruction: remote outputs (RY)
#0 to #7
TO instruction: remote inputs (RX)
FROM instruction: remote registers (RWw)
#8 to #23
TO instruction: remote registers (RWr)
#24
Transmission rate, hardware test set value
#25
Communication status
#26
CC-Link model code
#27
Set value of host station number
#28
Number of occupied stations, expanded cyclic set value
#29
Error code
#30
FX Series model code
#31
Not available
#32,#33
Treatment of link data
#34,#35
Not available
#36
Unit status
#37 to #59
Not available
#60 to #63
Consistency control
The 224 remote inputs (RX000 to RX0DF)
#64 to #77
These devices set the ON/OFF data to be sent to the master station when the TO
instruction (or direct buffer memory specification) is executed.
#78 to #119
Not available
The 224 remote outputs (RY000 to RY0DF)
#120 to #133
These devices read the ON/OFF data received from the master station when the
FROM instruction (or direct buffer memory specification) is executed.
#134 to #175
Not available
32 words (RWw00 to RWw1F) of remote registers
#176 to #207
These devices set the word data to be sent to the master station when the TO
instruction (or direct buffer memory specification) is executed.
#208 to #303
Not available
32 words (RWr00 to RWr1F) of remote registers
#304 to #335
These devices read the word data received from the master station when the FROM
instruction (or direct buffer memory specification) is executed.
#336 to #511
Not available
Link special relay SB
#512 to #543
The operator can check the data link status using the bit information of these
devices.
#544 to #767
Not available
Link special register SW
#768 to #1279
The operator can check the data link status using the word information of these
devices.
#1280-
Not available
R/W : Read/write is possible
R
: Read only
*1.
Read/write is only possible when the expanded cyclic transmission is set to "single."
*2.
When writing to an area without assigned link points, writing is invalid. When reading from an area
without assigned link points, the reading operation results in "0" being read.
*3.
Only a value of "0" can be written and accepted.
→ For details on the buffer memory, refer to Section 7.2.
Description
7 Buffer Memory
7.1 Buffer memory list
Read/Write
Reference
*1,*2
Subsection 7.2.1
R/W
*1,*2
Subsection 7.2.2
R/W
R
Subsection 7.2.3
R
Subsection 7.2.4
R
Subsection 7.2.5
R
Subsection 7.2.6
R
Subsection 7.2.7
*3
Subsection 7.2.8
R/W
R
Subsection 7.2.9
-
-
R/W
Subsection 7.2.10
-
-
R
Subsection 7.2.11
-
-
R/W
Subsection 7.2.12
*2
Subsection 7.2.13
R/W
-
-
R
Subsection 7.2.14
-
-
R
Subsection 7.2.15
-
-
*2
Subsection 7.2.16
R/W
-
-
R
Subsection 7.2.17
-
-
R
Subsection 7.2.18
-
-
33
1
2
3
4
5
6
7
8
9
A

Advertisement

Table of Contents
loading

Table of Contents