Checking Oven Broil Element Operation - Viking DSCD130 Service Manual

Hide thumbs Also See for DSCD130:
Table of Contents

Advertisement

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Checking Oven Broil Element Operation

Ensure house breaker or fuse is not open.
Disconnect power to the range.
Access control board assembly and wiring.
Connect power.
240 VAC present on control board connector
P1 red to P1 black?
Yes
RTD open or shorted?
(See fault codes on page 12).
No
Turn oven function selector to med broil.
5 VDC present red to black?
Yes
Turn oven function selector to med broil.
3.44 VDC present red to white?
1.56 VDC present black to white?
Yes
Turn thermostat to broil.
5 VDC present orange to blue?
Yes
Turn thermostat to broil.
1.66 VDC present orange to yellow?
3.34 VDC present blue to yellow?
Yes
240 VAC present on
control board P6 grey to P1 black (outer element)?
control board P6 violet to P1 black (inner element)?
Yes
240 VAC present K17 yellow to P6 grey?
240 VAC present K17 yellow to P6 violet?
No
Replace control board.
©2010 Viking Preferred Service
Repair or replace
No
defective wiring.
Yes
Replace RTD.
No
Replace control board.
Replace oven
No
function selector.
No
Replace control board.
No
Replace thermostat.
No
Disconnect power to the range.
Check broil element resistance.
Yes
No
Replace broil element.
Troubleshooting
Replace control board.
Inner broil element 22.0 ?
Outer broil element 38.8 ?
Repair or replace
defective wiring.
Yes
19