Advertisement

*Install LCD block
(6) TY-CNL-D1.7x3.5 (x2)
(7) CNL-D1.7x2.5
(8) [Confirm] You must feel click when turning electronic dial.
10. [CONF] CCD Base Plate Support Pillar
[Required equipment] Block gauge for 35mm, Dial gauge comparator, etc. (same as MZ series)
(1) Measure height of the CCD base support pillar (3 places) from the mount surface as shown in the figure.
(There are four kind of height)
Distinction
Last two digit of
lot number
Tolerance:
(Only fot 76700)
Using
Block
gauge for 35mm
(45.46mm)
Height of Pillar
Shape of plate for

0-C000

[-00]
49.876±0.02 mm
+4.416 ±0.02 mm
(+4.396~4.436 mm)
Previous parts (±0)
Previous oarts :
counterbore (-0.2)
76700 -36/94-
(7)
From [-01]
[-04] and later
to [-03]
49.676±0.02
49.640±0.02
+4.216 ±0.02
+4.18 ±0.02
(+4.196~4.236)
(+4.16~4.20)
New parts
(-0.2)
New parts:
No counterbore
No counterbore
(±0)
Borad
Tolerance :
t=1.6 (+0.01
+4.416
+4.
LCD block
[-13] and later
49.610±0.02
+4.15 ±0.02
(+4.13~4.17)
New Parts
New parts
(-0.236)
(-0.266)
New parts:
New parts:
No counterbore
(±0)
thickness
Modified Borad
thickness
Tolerance :
~-0.03)
t=1.6 (+0.03
~-0.01)
+4.216
,
+4.18
,
(6)
(±0)
+4.15
or
+0.416
+0.216
or
+0.18
or
+0.15
or

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents