Pentax K100D Service Manual page 66

Hide thumbs Also See for K100D:
Table of Contents

Advertisement

23-4. Procedure of adjustment
(1) Connect the AC adaptor to the camera.
(2) Connect the camera to the computer by the USB cable
(3) Attach the Master lens to camera while confirming the aperture of Master lens is set to F8.
(4) Turn the main switch ON, and then confirm that the camera is recognized as a [Removable
Disk] under [My Computer]
(5) Set the camera and master lens toward center of light window of LB3300, and then cover the
whole camera by using a dark curtain and so on.
(6) Start the adjustment software (CSAdjust.exe). Input ID number of master lens and then click
OK button.
[CAUTION] The adjustment software ends compulsorily while indicating the following error
message if ID number which is not correct is input and OK button is clicked. In that case, restart
the adjustment software and then input correct ID.
■Lens ID No. Input display
(7) The following window will be displayed when the adjustment software is started.
Wait for 20 seconds
76700 -65/94-
■ Error display

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents