Chart
22-3.Preparation
1) Set the zooming position at 200mm and distance ring
set at 2m and then fix each setting with tape
2) Attach lens to the camera
3) Set the camera to the following condition
Mode dial: M
AF switch: MF
SR switch: ON
4) Attach camera to the driving stage
* Driving stage must be the horizontal position.
5) Set the camera 1.9545m from the chart and match the chart with frame
of spot measurement in the view finder
22-4. Adjustment items
SR4: Gain adjustment
The adjustment that the amount of the correction becomes the best for an actual amount of the gap
SR mechanism
◆ Gain adjustment
補 正 機 構
76700 -61/94-
P C
防 振 ユ ニ ッ ト
SR Unit
手 ブ レ 量
Amount of Hand shake
補 正 量
Amount of corrected