Table of Contents

Advertisement

TM
ENGLISH
Product No. 76830
PENTAX Service Co.,Ltd
Technical Service Dep.
03.07H.Y.

Advertisement

Table of Contents
loading

Summary of Contents for Pentax K10D 76830

  • Page 1 ENGLISH Product No. 76830 PENTAX Service Co.,Ltd Technical Service Dep. 03.07H.Y.
  • Page 2: Table Of Contents

    [TABLE OF CONTENTS] PREPARATION…………………………………………………………………………….. 2 PREPARATION FOR ADJUSTMENT…………………………………………………… OUTLINE FOR DISASSEMBLY AND ASSEMBLY…............1. CAUTION……………………………………………………………………………… 2. ADJUSTMENT FLOW WHEN REPLACING T100 ………………………………….. 5 3. FLOWCHART FOR ASSEMBLE, ADJUSTMENT AND CONFIRMATION………... 6 DISASSEMBLY AND ASSEMBLY PROCEDURES............1. DISASSEMBLY PROCEDURE OF MAIN BODY…............. 8 2.
  • Page 3: Preparation

    PREPARATION The following preparations are required before disassembling and assembling the camera. 1. Prepare the Jigs, tools and testers. (Refer to the Table of Jigs, tools and testers.) 2. Make the preparation with referring next section of “Preparation of adjustment”. Preparation of Adjustments [Required equipment] Programmed software for 76830 (Supply with CD-ROM)
  • Page 4 When replace the light source or master lens for 76180 (D20 or D20-01), this calibration is necessary. [Required equipment] K10D Master body for calibration (PENTAX Corporation will rend the master body. Please contact with us) Adjusting software for 76830 Computer (Windows 2000 or Xp, support USB) Light source (Example: LV3300, A light source) Master lens for 76180 (D20 or D20-01) *Use the same master lens as the ID number printed on CD- ROM to adjust it accurately.
  • Page 5 (5) Surely set the camera and lens toward center of light window and cover the whole camera and light window by using a dark curtain. (6) Start the adjusting software [76830 MTest.exe] in [EXE] holder. (7) Input the lens ID number correctly then press [OK] button. (8) When start the adjusting software, following screen will be displayed.
  • Page 6: Outline For Disassembly And Assembly

    Outline of Assembly and Disassembly 1. Caution (1)Be sure to use the anti-static mat and wrist strap to prevent static failure of circuits. (2) This product is used lead free solder. Surface of solder will be white-tinged color. Solder quickly, because melting temperature is high and so if heat to much, it is possible to damage to PC board.
  • Page 7: Flowchart For Assemble, Adjustment And Confirmation

    3. Flowchart for Assemble, Adjustment and Confirmation page 2. ASSEMBLY AND DISASSEMBLY PROCEDURE OF FRONT HOUSING........ (1) FRONT HOUSING BLOCK......................18 (2) M1..............................(3) 0-G100............................(4) [CONFIRM] CHECKING THE MIRROR FUNCTION............(5) 0-S300............................. (6) A104 ……………………………………………………………………………………………… 22 (7) [ADJUST] POSITIONING 1ST AND 2ND MIRROR ……………………………………….. (8) [ADJUST] AF JOINT STROKE ……………………………………………………………….
  • Page 8 (17) 0-T100 (MAIN PC BOARD)......................(18) 0-T770 (PZ CIRCUITS BLOCK)………………………………………………………………. (19) SOLDERING T100 LEADWIRES……………………………………………………………... (20) 0-A51 (TRIPOD PLATE)……………………………………………………………………….. (21) [ADJUSTMENT] INITIALIZATION WHEN REPLACEING T100……………………… 21-1 PREPARATION………………………………………………………………………………… 21-2 POWER CHECK……………………………………………………………………………….. 21-3 INSTALLING FIRMWARE…………………………………………………………………… 21-4 WRITHING INITIAL DATA…………………………………………………………………… 40 (22) [ADJUSTMENT] SR ADJUSTMENT (UNIT ADJUSTMENT)……………………………. 40 (23) [ADJUSTMENT] 0-J100 POSITION ADJUSTMENT………………………………………...
  • Page 9: Disassembly And Assembly Procedures

    DISASSEMBLY AND ASSEMBLY PROCEDURES 1. Disassembly procedure of main body [Preparation] Remove the Hot shoe cover, Eye cap and Battery from the main body. 1. A401 (Bottom cover) [Caution] There is strong magnet in the CCD/SR blocks therefore please do not place a screw or magnetic card near the ②...
  • Page 10 ⑦ Discharge the main capacitor Lift up the A301 then discharge the main capacitor by using 100Ω-1kΩ resistor. (Discharge between Blue and Brown (gray) soldering land on T750.) 100~1kΩ ⑦ ⑧ Disconnect T51 flex board from connector. (Slide lock) ⑨ ⑨...
  • Page 11 ⑥ Put mount cover on the body to protect SI-LED and TV dial part. ⑦ Start from terminal side and then lift up the bottom side ⑧ Loosen the screw then remove a rug plate. ⑦-2 ⑧ ⑦ ⑥ Lug plate (27355-I17) Black (40mm) ⑨...
  • Page 12 5. 0-T100 (Main PC board) ① Peel off the BT (5x15)… (x6) ② Peel off T90 ③ Peel off U5 (76030- A35) ④ Unsolder 7 lead wires ⑤ Unsolder 2 lead wires ⑥ Unsolder 4 lead wires ⑦ Unsolder 6 lead wires ⑧...
  • Page 13 6. 0-T970(SD circuit block) ① Screw (x3) ② 0-T970 ① ② ② ① 7. 0-T770 (PZ Circuit block) ① Unsolder lead wire x2 (Brown and White) ③ ② Remove shoulder screw ③ 0-T770 8. 0-C000(SR/CCD block) [Caution 1] Pay attention, there is powerful magnet is carried in the inside of a CCD/SR block. [Caution 2] Since a performance is spoiled, a CCD/SR block cannot be disassembled and also don't apply the external pressure to a movable part [Caution 3] The flex from SR/CCD should be take care carefully, otherwise it will effect the performance of...
  • Page 14 9. O201 (LCD block) ① Unsolder 6 lead wires. ② Peel off [AE-L] SW from double stick tape. ③ Screw ④ ④ TY screw (x2) ② ③ ① ⑤ Lift up LCD block as shown figure below. ⑥ Disconnect O100 flex from connector. (Flip lock type) ⑥...
  • Page 15 11. 0-T700 (Upper right side flex board) ① Unsolder 12 lead wires. ② Unsolder 4 lands. (T71 flex board) ① ② ④ ③ Peel off flex board ④ TY screw (x2) ③ ⑤ ⑤ Screw (x2) ⑥ T700 ⑥...
  • Page 16 12. 0-T750 (Upper left side flex board) ① Unsolder 7 lands. (O170 flex) ③ ② ② Unsolder 10 lead wires. ③ Unsolder 7 lead wires. ① ④ Screw (x3) ⑦ ⑤ ⑤ TY screw ⑥ Peel off the flex of RAW SW ⑧...
  • Page 17 14. T901 (Lowe flex board) ① Unsolder T301/M100 flex land (20 lands) ② Unsolder two read wires / T901 ③ Screw ② ③ ④ ① ④ A141 15. A5 (Right shoulder plate) ① CSM screw ② ② TY screw ③ A5 and related parts. ③...
  • Page 18 18. 0-A101 (Front housing block) ① Supply DC2V to 0-S250 (Mirror motor). (Positive (+) on Red wire) Set the front housing block to mirror up position. ② Put mount cover on the body to protect SI-LED part. ③ Screws x5 ④...
  • Page 19: Assembly And Disassembly Procedure Of Front Housing Block

    2. Assembly and Disassembly procedure of front housing block *Disassemble the front housing block in reverse order of assembly procedures. 1. Front housing block B41, M120, (DT(4x15)), B58 x2, B59, TY-CNL-G 1.7x2.0, 0-B52 (mirror sheet), B66 (shaft) ----A screw lock (SL) and L115 are applied. B63, B57 B62 (spring) ---- Apply screw lock.
  • Page 20 3. 0-G100 ① ① Apply G126 at 13 positions and apply L115 at 2 positions. ② Install B20 to B11. L115 ② G126 ③ B11 ----Hook the spring to shaft of mirror sheet. [Caution] Caution for come off spring. ③ ④...
  • Page 21: 0-G100

    ⑰ Clean code plate by solvent and apply G151. ⑱ Latch the lever of G100 while pushing ⑰ down the sliding plate. ⑱ ⑲ 0-G100 ----Surely install G100 without any gap between plate. ⑲ Pink (60mm) ⑳ TY-CNL-D1.7x3.0 (x4) Purple (60) ⑳...
  • Page 22: [Confirm] Checking The Mirror Function

    4. [CONFIRMATION] Checking the mirror function [Required equipment] Power supply ① Confirm the following points while applying DC2V to the mirror motor. (Red wire: Positive) -1) The mirror seat must be moved smoothly without noise. -2) The shutter charge lever(b) and sliding plate(a) must be moved smoothly and surely go up and down. ②Set the mirror seat to the down position while applying DC1.5V.
  • Page 23: A104

    6. A104 ① ① 0-A121 ② A133 G134 ② ③ TY-CNL-F1.4x4.0 ③ ④ 0-A126 and related parts Apply G134 as shown in figure. ④ ⑤ ⑤ TY-CNL-D1.7x3.0 G134 G134 ⑥ A105 -- Apply G134 as shown in figure. ⑦ A110 ⑧...
  • Page 24: Adjust] Positioning 1St And 2Nd Mirror

    7. [ADJUST] POSITIONING 1ST AND 2ND MIRROR [Required equipment] 1 mirror angle (45°) adjusting jig, Mirror angle adjusting jig for 27830 (need modify),Mirror positioning scope. *Adjustment is performed by turning B58 (2 pcs). The Y-axis (the vertical direction) is adjusted to a 0 target.
  • Page 25: [Adjust] Af Joint Stroke

    ② 8. [ADJ] AF Joint stroke [Required equipment] Vernier calipers ① ① Set the AF lever (0-A115) to the AF.C position. ③ ② AF coupler(0-S300) must be projected from the mount surface by 1.2mm or more. ③ When the mount lock pin comes to the mount surface with depressing the mount lock lever, the AF coupler ④...
  • Page 26: Adjust] Viewfinder Focus And Parallax

    11. [ADJUST] VIEWFINDER FOCUS AND PARALLAX [Required equipment] 50mm lens, Collimator, Focus master lens [ Preparation] 1. Adjust the diopter by the diopter adjustment lever. 2. Set the AF mode switch to to MF position. (Upper position) 11-1. Parallax [Caution] Confirm that the Pentaprism must be installed securely. ①[Confirmation]Confirm there is neither gap nor an inclination at an upper and lower, Right and left position.
  • Page 27: Adjust] Positioning Si-Led

    13. [ADJUST] POSITIONING SI-LED [Required equipment]Power supply, lead wires ① Solder and arrange the lead wires on 0-O170 as shown in the figure below. [Caution]Do not stress to the lands of 0-O170. : SI-LED AF frame ② Apply DC3.2V to 0-O170, and confirm the positioning And lighting of SI-LED 11points.
  • Page 28: Adjust] Positioning 0-O100 (Viewfinder Indications)

    15. [ADJUST] POSITIONING 0-O100 (VIEWFINDER INDICATIONS) Preparation: O100 cable for 76830, O100 positioning jig for 76700, Power supply (8V, 3A). 15-1 Preparation ① Connect the 0-O100 cable for 76830 to the jig as shown figure. ③ ① ② Connect the flex board of 0-O100 to the cable. DC6V ③...
  • Page 29: 0-J100

    17.0-J100 ② ① M10 -- Set the diopter lever at end of left side and ③ ① then install it. ② 0-J100 ③ M5-TY-CNL-G1.7x5.0(Temporary) [Caution]--- Disassembly 1. Set the Diopter lever to the left side. 2. Unscrew TY-CNL-G1.7x5.0 -M5. 3. Remove the bonds which are around the 0-J100. * Not to damage 0-J100 4.
  • Page 30: Assembly Procedure Of Main Body

    3. ASSEMBLY PROCEDURE OF MAIN BODY ③ ① 1. 0-E000 (Shutter block) ① Main body ④ ② 0-E000 ② ③ A70 x3 (Shoulder screws) ③ *Tighten A70 in numeric order. ① ④ Arrange 5 lead wires by DT (5x5) as shown in figure. *After install, 0-E000 has a little movement.
  • Page 31: Front Housing Block

    ② A13 ③ Main body ④ TY-CNL-D1.7x4.0 x2 ③ ④ ② 3. 0-A101 (Front housing block) ① ① Apply DC 2V to the mirror motor, and set mirror up position. (Red --- +) ② To prevent the damage of SI-LED, attach mount cover. Then put downward. ③...
  • Page 32: 0-Q200 (Flash Pc Board)

    5. 0-Q200 (Flash PC board) ① 0-Q200 --- Arrange the lead wires as shown figure. ② TY-CNL-D1.7x3.5(bottom side) ④ ③ A117 ④ TY-CNL-D1.7x3.5 ③ ① ② 6. A5 (Right shoulder plate) and related parts ① A5 and related parts ② -- Arrange the lead wires as shown figure.
  • Page 33: 0-T750 (Top Left Flex Board)

    ② Arrange the lead wires and flex as shown figure then install 0-A3. ③ TY-CNL-D1.7x4.0 x3 ③ ④ CNL-D1.7x2.5 x2 ⑥ ⑤ TY-CSM1.7x4.0 ⑦ ⑥ TY-CNL-E1.7x2.2 Ni x2 ⑦ Arrange T901 flex and 0-A3 ② ⑤ as shown in figure. ④...
  • Page 34: 0-T700 (Top Right Flex Board)

    10. 0-T700 (Upper right side flex board) ① 0-T700 --- Attach to the body ② CNL-D1.7x1.6 x2 ③ TY-CNL-D1.7x3.5 x2 ④ Fix flex with DT (10x4) ⑤ Solder 4 lands. (T71 flex) ⑥ Solder 12 lead wires. ② ③ ④ ①...
  • Page 35: A350 (Main Swithch Base Plate)

    ② 11. A350 (Main SW plate) ① A350 ③ ② CNL-D1.7x3.0 ① ③ TY-CNL-D1.7x4.5 ④ Fix the flex which around release SW/Green button SW with DT (5x5) ⑤ Arrange the lead wires with BT (6x15). ④ ⑤ 12. O201 (LCD block) ①...
  • Page 36: Confirm] Ccd Base Plate Support Pillar

    13. [CONFIRM] CCD BASE PLATE SUPPORT PILLAR [Required equipment] Block gauge for 35mm, Dial gauge comparator, etc. (same as *istD or K100D ) ① Measure height of the CCD base support pillar (3 places) from the mount surface as shown in the figure. Tolerance (For 76830 only): 49.45±0.1 mm With using Block gauge for 35mm (45.46mm):...
  • Page 37: Adjustment] Height Of 0-C000

    [Caution] When replacing 0-C000: 1. There is CCD ID No. seal on the plate. *The No. can be readable. 2.Peel off the seal on the plate then replace the seal on the pentaprism. 15. [ADJUSTMENT] HEIGHT OF 0-C000 [Required equipment] Block gauge for 35mm, Dial gauge comparator, etc. (same as *istD series or K100D) Specified glue: Cemedine Super-X (Clear) --- Order number 95901 A133 ①...
  • Page 38: 0-T970 (Sd Circuits Block)

    16. 0-T970 (SD circuit block) ① 0-T970 --Arrange the 4 lead wires as shown figure. ② TY-CNL-D1.7x3.5(x3) ② ① 17. 0-T100 (Main circuit block) ① Set up T100 as shown figure. ② ② Connect 3 flex. (Plug-in type) ③ ③ Attach T100 to the body and connect to the Connector.
  • Page 39: Soldering T100 Leadwires

    19. Soldering lead wires on T100 ① Connect flex to connector. (2 point, Flip lock type) Fix J100 flex with DT ② Connect flex to connector. (2 point, Plug-in type) ③ Solder 4 lead wires. ④ Solder 6 lead wires. ⑤...
  • Page 40: 0-A51 (Tripod Plate)

    ① ② 20. 0-A51(Tripod plate) ① 0-A51 ② CNL-D1.7x2.5 x4 ③ Arrange lead wires as shown figure. (S300 and T770) DT(4x15) DT(4x10) ② 21. [Adjustment] Initialization when replacing T100 [Caution] When replacing T100, you must execute this initialization. Do not execute with other reason. [Required equipment] SD card SD card 2 pieces (FW for replacing T100, for install initial data), TV monitor, Exclusive Video cable, Circuit tester, AC adaptor (or DC cord for 76830, Power supply DC8.3V/3A or above)
  • Page 41: Writhing Initial Data

    21-4. Data initialization [Caution] If execute this initialization, all EEPROM data will be initialized (Cleared) ① Install SD card (For data initialization) to the camera. ② Connect the AC adaptor. (Initialization will be started. (1) Install SD WAIT It takes approx 20 sec.) card (For data...
  • Page 42 ⑦ CCD number input screen is displayed. ⑧ Select Input or Skip and execute the program. <Not replace T100 or C000> Click [Skip] <Replaced T100 or C000> Input I-CCD number twice. Click [IMPUT] * If cancel the adjustment, click [CANCEL] ⑨...
  • Page 43: [Adjustment] 0-J100 Position Adjustment

    23. [Adjustment] Positioning 0-J100 [Required equipment] Penlight or equivalent *Adjustment and confirmation are the same as K100D. Refer to the service manual of 76700. ① [Confirm] Tolerance Center position of sensor Tolerance:0.25~0.85mm Center position of Viewfinder Photo sensor (0-J100) AF frame for spot metering (φ2.5) ②...
  • Page 44: (24 )[Confirmation] Confirm Sealing For Outside

    24.[Confirmation] Sealing on Body [Confirmation] The sealing should be installed correctly and without any dirt, dust and sand. ① Front and back side electric dial. [Confirmation] When rotate the electric dial, it should not touch with a proof sheet. A353 A352 A355 A352...
  • Page 45 ③ A150 A451 A453 A453 ④ A201 A474 x2 A451 A204 A456 A457 A456...
  • Page 46 ⑤ A301 A461 A462 A460 A472 A455 ⑤ A401 A454 [Caution] • Pay attention that sealing material should not pulling or twisting • Install the sealing material carefully, especially when install the part of the curve, especially the periphery of A301, A401, and M311 •...
  • Page 47: A150/A201 (Front Cover/Back Cover)

    25. A150 and A201(Front cover and Back cover) ① M311 ② CNL-D1.7x3.0 x2 ③ Prevent the damage of SI-LED and Tv dial attach mount cover. ④ A98(O-ring)---There needs to be no adhesion of crushing, a crack, dust, etc in O-ring. ⑤...
  • Page 48: A301(Top Cover)

    26. 0-A301(Top cover) * The brush should be without bend * Apply G151 to the main SW land. ① A27(Water proof sheet) ① ② 0-A301 G151 ③ Solder 5 lead wires. ④ Connect the T51 flex to the connector(Slide lock) ⑤...
  • Page 49: [Confirmation] Function Check 1

    27. [Confirmation] Function check 1 [Required equipment] Battery adaptor for 76830, DC code for 76830, Regulated DC power supply (8V/3A), SD card, Circuit tester, Lens for checking (FA50mmF1.4), Battery grip D-BG2, Cable switch CS-205, remote control F, Flash for checking (AF360FGZ etc) 27-1.
  • Page 50: Adjustment] Flash Store Position

    ⑨ When [+/-] button is pressed, light on the back light of LCD panel and exposure compensation can be set. ⑩ When press AE-L button, AE lock can be set ⑪ When press exposure bracket button, it can be set. ⑫...
  • Page 51: [Adjustment] Slr Operation Adjustment

    27-8. Check Aperture control and CCD ① Attaching the lens to the camera. Set the focus mode and Capture mode to MF and B. ② The aperture of lens must change similarly when the aperture value (Av) is set in opening, the middle, and the minimum with the Av dial.
  • Page 52 28-3. adjustment ① Click [Op] icon to start connection. (USB open) *Confirm that [Connect] is displayed on USB IO. ② Follow the screen and adjust or check. 76830 Connect Initialize the data [CAUTION] Select [NO] otherwise SR adjustment data will be cleared. Replaced Main PCB?...
  • Page 53 3:AF AND RELATED ADJUST ↓ Method for [CCD POSITION ADJUST] ① Remove the bottom cover. (Leave power and USB cable) ② Remove 3 screws. ③ Pull front cover to front side and put driver then turn the adjustment screw. 6:BATTERY LEVEL ADJUST ↓...
  • Page 54 ③ Change the select SW to battery and click [OK]. (Indicate setting voltage of battery side as shown in figure -- [2]) ④ Change the select SW to Grip and click [OK]. (Indicate setting voltage of D-BG2 side as shown in figure -- [3] ⑤...
  • Page 55: Af Shift Adjustment (Optional)

    28-4. AF shift adjustment (Optional) *If AF does not improve by AF focus adjustment and there is no other factor, execute AF shift adjustment if necessary. ① Click □ button as shown in fig. ② Input [AFS] by capital letter and press [Enter] key. ③...
  • Page 56 29.[Adjustment]SR adjustment 2 (Gain adjustment) *It is the same adjustment with K100D except adjusting software and power source. [Caution-1] Execute this adjustment when replaced T100, T970 and C100 block. [Caution-2] [SR adjustment- 1] should be completed before this adjustment. [Caution-3] Do not give the camera the vibration when you adjust it. Put on the sturdy and stabile table.
  • Page 57: [Adjustment] Sr Adjustment (Gain Adjustment)

    30. [Adjustment] Digital [Caution]If execute this initialization, all setting will be initialized except custom function. [Required equipment] Programmed software for 76830(Digital), Computer (Windows 2000 or XP with USB port equipped ) Light source (LB-3300: A light 2850 Kº±10, LV11.00), Master lens for 76180 (95901 D20), Diaphragm set ring F8 (KA-0-1A), AC adaptor (D-AC10), USB cable (I-USB17), Dark curtain, Color temperature tester (for calibration), LV meter (for calibration) *The adjustment method is the same as K100D.
  • Page 58: [Adjustment] Digital Adjustment

    ② Set the light source to LV12 and press[OK]. ③ Set the light source to LV11. ④ When following screen is displayed, adjustment is completed. *If adjustment is NG, refer to Technical information [Table of Error code]...
  • Page 59: Wdc Adjustment (Optional)

    30-4. WDC Adjustment procedure *The adjustment method is the same as K100D. Refer to the service manual of 76700. *There is possibility that CCD pixel defect compensation can be adjusted by adjust repeatly. 31. [Adjustment] Shutter speed adjustment by histogram *The adjustment method is the same as K100D.
  • Page 60: Confirmation For Sr Function

    This confirmation is listed for [Method of confirmation for SR function on service] [Preparation] Computer, Battery (or AC adaptor), USB cable, 50mm lens, SD card (for taking picture), Image viewing software (e.g. PENTAX PHOTO Browser , ACDSee Adobe Photoshop, other) ①...
  • Page 61: Technical Information

    33-3. FW version up *Version up latest FW if necessary,. Method for version up is the same as K100D. Refer to the Service Manual of 76700 for details. TECHNICAL INFORMATION Battery consumption current Condition : Lens [FA lens, A position], each mode and setting is default setting. Lens --- ○: With ×: Without SD card --- ○: With...
  • Page 62: Block Diagram

    Block Diagram...
  • Page 63 Table of Error Code (SR unit adjustment) When adjustment error is occurred, below screen will be displayed. [Table of Error Code for SR unit adjustment] (aa-bb) Error code Contents DUTY ERROR (X axis) X axis DUTY level error DRIVE ERROR (YL,YR axis) Y axis driving error DUTY ERROR (YL,YR axis) Y axis DUTY level error...
  • Page 64 Table of Error Code (SR Gain adjustment) When adjustment error is occurred, below screen will be displayed. 7683 [Table of Error Code for Gain adjustment] (aa-bb-xx) (aa) (bb) (xx) 00 initialization 01 Read configuration file Can't found setting file. Can't Power on 02 Initialize USB 02, 03 Command error (Communication error) Can't use this program (This program for another model)
  • Page 65 Table of Error Code (Digital adjustment) When adjustment error is occurred, below screen will be displayed. [Table of Error Code for Digital adjustment] AA - BB - CC - DD - EE AA: Adjusting item AA: Initialize check Initialize CCD data display CCD Information WB Adjustment Pre-Process Gain...
  • Page 66: Ae Program Line And Apex Chart (Iso200)

    AE Program line (normal) and APEX chart (ISO200) * Standard program exposure mode (DA F 3.5-5.6 / 18-55mm) * Standard program exposure mode (FA F 1.4/50mm)
  • Page 67: Feature Of K10D

    ⑤ Center plate ⑥ Support ball M:Hyper Manual NEW CCD ⑦ Rear plate Sv:Sensitivity-Priority mode 10M TAv:Shutter/Aperture-Priority mode Dust –proof, Water-resistant construction Newly developed 22bit A/D converter Newly developed 〝PRIME (PENTAX Real Image Engine) K10D DDR2 Memory SDHC Memory card D-BG2 Interface...
  • Page 68: Information Of Jigs, Tools And Testers For K10D

    INFORMATION OF JIGS, TOOLS AND TESTERS FOR K10D Order No. * Exclusive use for K10D (76830) No.95901-P410 Program soft for 76830 (For SLR/digital/SR adjustment) Battery Adaptor for 76830 (BATT level adjustment/ battery consumption check) No. 95901-D26 DC cord for 76830 (DC input terminal, battery consumption check) No.
  • Page 69: Af Confirmation Chart And Scale

    Confirmation chart for AF and scale Ver.2...

Table of Contents