*Confirmation: [Connect] should display as follow
76700
⑦ Execute the check/adjustment following the display screen as follows
T100ExChange
Did you exchange the
main pc board?
Replaced Main PCB?
No
1:EEPROM CHECKING
2:EXPOSURE ADJUST
[BV ADJUST]
↓Tools:Focus master lens for 35mm (KML-01), Diaphragm set ring F8 (KA-0-1A)
↓Light source (LV6,LV8,LV12,LV15) or (LV6,LV9,LV12,LV16)
3:AF AND RELATED ADJUST
↓Tools: AF positioning jig (Square) for 27830, AF positioning jig (Cross) for 27250, Light source LV12
↓Driver1.5mm (HD-M1.5), AF master lens for 2m, FA (F) 35-80mm F4-5.6,
↓ AF chart for 2m x2 (Exclusive item), FA Macro 50mmF2.8,
※ 2m AF chart have to be set as follows
1)Distance between chart and mount of camera --- 1,954.5mm(=1.9545m)
2)Chart should be set at perpendicularly against light axis of the lens
[CCD POSITION ADJUST]
ADJUSTMENT
1) Alpha-CROSS -- . - Dump Start -- . Adjustment -- . Stop
2) Focus --- Start - . - Next . Stop . Close
* When replaced M100, Click M100 button and then start adjustment
PDC Adj
Yes
Writing of initial EPROM.
6:BATTERY LEVEL ADJUST
76700 -58/94-
Connect
Initialize the data
(Yes/No)