⑲ 0-G100
----Surely install G100 without any gap between plate.
⑳ TY-CNL-D1.7x3.0(x4)
【Arrangement when replace G100】
1. Arrange the lead wires with DT(5x15) as shown in figure
2. Solder 4 lead wires.
3. Two lead lines are passed through S364
[Notice for Disassembly] Set the mirror seat at top position before removing 0-G100.
1. As shown in a figure, a gear is turned, and it sets to a mirror up position.
[Caution] Since there is no stopper B65 of a mirror, don't carry out by turning on electricity to a
mirror motor absolutely.
Mirror up: (Shutter charge lever(1) and mirror seat(2) and sliding plate(3) must be top end
position. )
2. Latch the lever of G100 while pushing down the sliding plate.