M301; S1 Block; [Adjust] Viewfinder Focus And Parallax; Parallax - Pentax K100D Service Manual

Hide thumbs Also See for K100D:
Table of Contents

Advertisement

10. M301

① Eyepiece (M301,L7 and other)
② TY-CNL-D1.7x4.0(x2)
11.SI block
① Confirm that there is neither dust nor scratch on inside prism and mirror.
② SI block(0-M51, 0-M52, M53, L11, L12, 0-O170 and other)
③ Attach M55 (SI spring) as shown figure
④ TY-CNL-F1.7x4.5(x2)
--- Install SI block and M55(spring) to the pentamirror side as shown figure
12. 【ADJ】 Viewfinder focus and parallax
【Required equipment】 50mm lens, Collimator, Focus master lens
【 Preparation】
1. Adjust the diopter by the diopter adjustment lever.
2. Set the AF mode switch to to MF position.(upper position)

12-1. Parallax

【Caution】 Confirm that the Pentaprism must be installed securely.+
①【Check】Confirm there is neither gap nor an inclination at an upper and lower, Right and left position.
Standard: Right/Left Less than 1°
Upside down Less than 1°50'

12-2. Viewfinder focus

① 【Check】Check a viewfinder focus.
* One scale for focus master lens is 0.03mm.
Standard: 0±0.07 mm
76700 -27/94-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents