3. Updating Firmware Version (2)

[Required equipment] Latest product Firmware for customer update (SD card),
AC adaptor, fully charged battery.
[CAUTION]
1. If power is shut down during updating firmware, electric part in the camera will be damaged.
2. When executing this updating, the camera will not be set default setting.
(1) Install the battery and connect the AC adaptor to the camera.
(2) Insert the SD card into the camera.
(3) Closes the SD card cover.
(4) Turn the main switch to ON while pressing [MENU] button.
(5) When program update screen is displayed as shown in figure.
Select [YES] by pressing the four-way key then press OK.
Update will be started. (It takes approx. 60sec for loading
firmware)
[CAUTION] Do not turn OFF the camera while loading.
* FW version for customer is displayed at this point.
(6) When [COMPLETE] is displayed, turn the camera OFF.
(Updating is completed)
76700 -81/94-
NOW LOADING
PROGRAM UPDATE
YES
NO
CURRENT VERSION 1.00
UPDATE VERSION 1.00
UPDATING
P**** 2/2
COMPLETE