Heater - Graco Reactor E-10hp Instructions Manual

Hide thumbs Also See for Reactor E-10hp:
Table of Contents

Advertisement

Heater

Test Heater Element
1. See Before Beginning Repair, page 40.
2. Wait for heater to cool.
3. Remove heater shroud (90) and electronics cover
(55).
F
. 15
IG
332144E
4. Disconnect heater element wires from heater wire
Remove Heater Element
1. To remove heater element (307), first remove ther-
55
90
2. Remove heater element (307 or 316) from housing
3. Inspect element.
NOTE: It should be relatively smooth and shiny. If there
is a crusted, burnt, ash-like material adhered to element
or sheath shows pitting marks, replace element.
4. Install new heater element (307 or 316). Hold mixer
ti21845a
5. Reinstall thermocouple, page 50.
6. Reconnect heater element leadwires to heater wire
7. Replace heater shroud (90) and electronics cover
Line Voltage
The primary heaters output their rated wattage at their
nominal voltage of either 120VAC or 230VAC, depend-
ing on system. Low line voltage will reduce power avail-
able and the heaters will not perform at full capability.
connector. Test with ohmmeter. Replace heater ele-
ment if the resistance reading does not fall within
the range.
Nominal
Heater
Heater
Wattage Per
Voltage
Zone
120
1500
230
2000
mocouple (310) to avoid damage, see step 7,
page 50.
(301). Be careful not to spill any fluid left in housing.
(309) so it does not block thermocouple port (P), for
(307) only.
connector.
(55).
Repair
Element
Wattage
Ohms
500
24-32
1000
12-16
620
73-94
1380
32-43
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents