Repair

Repair

Remove Immersion Heater

1. Turn off power to system. See the XM Operation
manual.
2. Drain Heating Fluid. See page 18.
3. Remove screws (HS) and immersion heater cover
(HC).
F
. 28: Connect Immersion Heater
IG
4. Disconnect white, black, and green wires from
power cable (303).
5. Loosen bushing (302) and pull power cable (303)
out of bushing.
6. Slowly remove immersion heater (L) from hopper
(D).
NOTICE
To prevent damage to the heater element coils,
ensure fold-back end of heater coil can pass back
through threaded opening of hopper (D).
7. Inspect the heater element coils for excessive corro-
sion. If necessary, replace entire immersion heater.
8. To install immersion heater (L) see Immersion
Heater Kit 256257 on page 12.
20
303
302
HS
HC
Remove Fluid Outlet Assembly
Kit
1. Drain Spray Material. See page 19.
2. Loosen fitting (212) or (211).
3. Loosen fitting (202).
4. See Installation on page 9 for assembly instruc-
tions.