Fill Wet-Cups; Fill Fluid Tanks - Graco Reactor E-10hp Instructions Manual

Hide thumbs Also See for Reactor E-10hp:
Table of Contents

Advertisement

Setup

Fill Wet-Cups

Keep the felt washers in the pump wet-cups saturated
with Graco ISO pump oil, Part No. 217374. The lubricant
creates a barrier between the ISO and the atmosphere.
Pump rod and connecting rod move during operation.
Moving parts can cause serious injury such as
pinching or amputation. Keep hands and fingers
away from wet-cup during operation. Shut off Motor
Power
before filling wet-cup.
Fill wet-cups through slots in plate, or loosen screws
and swing plate aside.

Fill Fluid Tanks

NOTICE
To prevent cross-contamination of fluids and equip-
ment parts, never interchange (isocyanate) and
(resin) parts or containers.
Have at least two 5 gal. (19 liter) pails to transfer fluid
from drums to supply tanks. Label one pail "ISO" and
the other "RES", using the red and blue labels pro-
vided. Always double-check which material you have
before pouring it in the supply tanks. Pouring is easier
if pails are not filled to the top.
Open only one supply tank at a time, to avoid splash-
ing material from one tank into the other when filling.
NOTE: Using a drill and mixing blade, mix filled or sepa-
rated materials in the pail before adding to the tanks.
Material left in the tanks overnight may need to be
remixed in the tanks.
18
1. Lift hose rack. Remove tank cover and pour ISO
into tank (red side, with desiccant filter in cover).
Replace cover
.
1
ISO
1
Add thin coating of grease lubricant to tank o-ring
if lid is difficult to assemble to tank.
NOTE: Desiccant filter is blue when fresh, and turns
pink when saturated. Be sure shipping plugs are
removed from openings on desiccant filter.
2. Remove tank cover and pour resin into RES tank
(blue side). Replace cover
RES
.
1
332144E