Repair Primary Heater - Graco Reactor 2 E-30 Operation - Repair - Parts

Proportioning system
Hide thumbs Also See for Reactor 2 E-30:
Table of Contents

Advertisement

Repair Primary Heater

Replace Heater Element
1. Press
to stop the pumps.
2. Turn off heat zones.
3. Flush pump.
4. Press
to park the pumps in the down position.
The park operation is complete when green dot
goes out. Verify the park operation is complete
before moving to next step.
5. Press
to deactivate the system.
6. Turn main power switch off.
7. Relieve pressure.
Pressure Relief Procedure, page
333024N
See
49.
8. Wait for heater to cool.
9. Remove four bolts (23) and shroud (10).
10. Remove screw (20) and lower din rail cover (48).
11. Disconnect heater wires:
a. A Side: Disconnect A side heater wires,
transformer, and transformer fan wires from
lower din rail (33).
b. B Side: Disconnect B side heater wires and
remove lower din rail (33) from B side heater
(5).
12. Test heater wires with ohmmeter.
System
Total
Heater
Wattage
E-30 (10
10,200
kw)
E-XP2,
15,300
E-30 (15
kw)
To prevent a short circuit or lowering the
transformer life, do not splash fluid on
transformer. Cover transformer with a plastic
sheet or piece of cardboard.
Repair
Element
Ohms
2,550
18–21 per
element
2,550
18–21 per
element
NOTICE
67

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reactor 2 e-30 eliteReactor 2 e-xp2Reactor 2 e-xp2 elite272010272011272110 ... Show all