Menu item setting/changing (Halogen, Fluorescent, Outdoor Mode)
 Electronic shutter step/synchro scan setting
[Step/Synchro: Off, 1/100 to 1/10000 (Step),
61.19 Hz to 1466 Hz (Synchro Scan)]
This setting is possible only when "Step" or "S/Scan" is
selected in electronic shutter mode setting.
• When "Step" has been selected as the electronic shutter
mode setting:
Off:
Electronic shutter is turned off.
1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000:
Electronic shutter operates at one of these
speeds as selected.
• When "S/Scan" has been selected as the electronic
shutter mode setting:
Bar noise can be reduced by synchro-scan adjustment
in shooting workstation scenes, for example.
Notes
 If the lens iris switch is at M (Manual), ELC may not
function. Set the lens iris switch to A (Auto).
 Flickering may increase at ELC under fluorescent
lights.
 Gain setting [Gain: Auto, –6 dB to 18 dB]
Auto: The light quantity is adjusted automatically.
–6 dB to –1 dB:
This setting makes it possible to shoot at the
optimal gain setting under conditions where the
light quantity is high. When it is used, images with
minimal noise can be shot but the dynamic range
is reduced.
0 dB: 0 dB should be selected in normal cases.
1 dB to 18 dB:
Use this range if sufficient video output cannot
be obtained even when the lens iris is opened in
shooting dark scenes.
 AGC maximum gain setting
[AGC Max Gain: 6 dB, 12 dB, 18 dB]
This is used to set the maximum gain up when "Auto" has
been selected as the gain setting.
 Black level setting [Pedestal: –150 to +150]
The black level (pedestal) of the luminance (Y) signal can
be set.
Used in adjusting the black levels of two or more
cameras.