WIRING DIAGRAM

This heater does not require a 120V A.C. supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries.
In case of a power failure, the burner switch and the optional remote control will continue to operate if batteries are installed in the receiver.. However, a 120V
A.C. power supply is needed for the fan/blower operation.
(Do not cut the ground terminal off under any circumstances.)
NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case
the fan is installed at a later date.
AC Adaptor
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.

AERATION ADJUSTMENT

The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude. Open the air shutter for a blue flame by
pulling down on the rod or close for a more yellow
flame by pushing up on the rod.
Proflame System
Configuration
886 GTMF
885
Wire Diagram
SureFire™ Switch
Minimum Air Shutter Opening:
NG
NG with Logs
NG with Stones
LP
LP with Logs
LP with Stones
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
1/16"
3/16"
3/16"
3/16"
Full open
Full open
Horizon
installation
1 of 10
CAUTION:
Carbon will be produced if air shutter is tightly
closed.
Note: Any damage due to carboning
resulting from improperly setting
the aeration controls is NOT covered
under warranty.
®
HZ33CE-10 Gas Fireplace
|
33
|
33