Venting Introduction - Regency HZ33CE-NG10 Owners & Installation Manual

Hide thumbs Also See for HZ33CE-NG10:
Table of Contents

Advertisement

installation
|
16

VENTING INTRODUCTION

The HZ33CE uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner
draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room
air up the chimney.
There are several vent systems approved for use with the HZ33CE: (see following "Venting" Sections for more details on approved vent systems).
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid
fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. (See "Rigid
Pipe Venting System" for more details and exceptions).
NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.
16 |
®
Horizon
HZ33CE-10 Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hz33ce-lp10

Table of Contents