Horizontal Venting with Three (3. 90
One 90
Option
V
H
A)
2' Min.
1' Max.
B)
3' Min.
2' Max.
C)
4' Min.
3' Max.
D)
5' Min.
4' Max.
E)
6' Min.
5' Max.
F)
7' Min.
6' Max.
Vertical Venting with Two (2. 90
One 90
elbow = Two 45
o
Option
V
H
A)
1' Min. 4' Max.
B)
2' Min. 5' Max.
C)
3' Min. 6' Max.
D)
4' Min. 7' Max.
E)
5' Min. 8' Max.
Elbows
o
elbow = Two 45
elbows.
o
o
V + V1
H + H1
With these options,
maximum total pipe
3' Min.
4' Max.
length is 30 feet with
minimum of 12 feet
4' Min.
5' Max.
total ver tical and
maximum 9 feet total
6' Min.
6' Max.
horizontal.
8' Min.
7' Max.
P l e a s e
m i n i m u m 1 f o o t
10' Min.
8' Max.
between 90
is required.
12' Min.
9' Max.
Elbows
o
elbows.
o
V + V1
With these options,
maximum total pipe
2' Min.
length is 30 feet with
minimum of 6 feet total
3' Min.
vertical and maximum 8
feet total horizontal.
4' Min.
Please note minimum
5' Min.
1 foot between 90
elbows is required.
6' Min.
n o t e
elbows
o
Vertical Venting with Two (2. 90
Option
H + H1
A)
2' Max.
B)
3' Max.
C)
4' Max.
D)
5' Max.
o
E)
6' Max.
For additional vertical venting with
2 x 90
o
elbows, refer to "Rigid Pipe
Venting Arrangements" Section.
installation
Elbows
o
One 90
elbow = Two 45
elbows.
o
o
V
With these options, maximum
total pipe length is 30 feet
2' Min.
with minimum of 6 feet total
vertical and maximum 6 feet
3' Min.
total horizontal.
4' Min.
Please note minimum 1
foot between 90
5' Min.
required.
6' Min.
Horizon
®
HZ33CE-10 Gas Fireplace
|