Fill the radiator until the coolant comes
out by the thermostat housing hole.
Install the bleeding screw then re-
move the hose pincher.
Complete the radiator filling.
Check the level in the coolant reservoir
and refill if necessary.
Run engine at idle with the radiator
cap off. Slowly add additional coolant
if necessary.
At this point, wait until engine reaches
normal operating temperature. De-
press the throttle lever two or three
times; then add coolant if required.
_____________________
132
Install radiator cap. Inspect all connec-
tions for leaks and check coolant level
in the reservoir.
Valve Adjustment
Valve adjustment is not required on
this engine.
Spark Arrester
The muffler must be periodically
purged of accumulated carbon.
WARNING
Never run engine in an enclosed
area. Never perform this opera-
tion immediately after the engine
has been run because exhaust sys-
tem is very hot. Make sure that
there are no combustible materi-
als in the area. Wear eye protec-
tion and gloves. Never stand be-
hind the vehicle while purging ex-
haust system. Respect all applica-
ble laws and regulations.
Select a well-ventilated area and make
sure the muffler is cool.
Place transmission on PARK position.
Remove the cleanout plug from muf-
fler.
1
V04C0DY
TYPICAL — TRAXTER MAX CVT
1. Clean-out plug
2. Muffler