Technical Data - Riello RL 190/M Installation, Use And Maintenance Instructions

Kerosene and gas oil burner
Table of Contents

Advertisement

4.3

Technical data

Model
Type
Output
(1)
Delivery
(1)
Fuel
Kerosene
net calorific value
density
viscosity at 20 °C
Gas oil
net calorific value
density
viscosity at 20 °C
Operation
Nozzles
Standard applications
Ambient temperatur
Combustion air temperature
Electrical supply
Auxiliary power supply
Electric motor
Ignition transformer
Pump
delivery (at 12 bar)
pressure range
fuel temperatur
Electrical power consumption
Electrical protection
Noise levels
(3)
Reference conditions: ambient temperature 20°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated
(3)
output.
Technical description of the burner
nd
2
stage
kW
Mcal/h
kg/h
st
1
stage
kW
Mcal/h
kg/h
kWh/kg
Mcal/kg
kg/dm
3
mm
/s max
2
kWh/kg
Mcal/kg
kg/dm
3
mm
2
/s max
number
°C
°C max
V/Ph/Hz
V/Ph/Hz
rpm
W
V
A
V1 - V2
I1 - I2
kg/h
bar
° C max
W max
dB(A)
Gas oil and Blends of gas oil and bio fuel (FAME in accordance with EN
14214) up to 10%
Intermittent (min. 1 stop in 24 hours). These burners are also fiitted for
the continuous operation, if they are equipped with the control box
LANDIS type LOK 16.250 A27 (interchangeable with the burner control
box LANDIS LAL 1.25)
Progressive two-stage (modulating by Kit)
Boilers: water, steam, diathermic oil
9
GB
RL 190/M
674 T1
1423 - 2431
1224 - 2091
120 - 205
534 - 1423
459 - 1224
45 - 120
11.97
10.3 (10.300 kcal/kg)
0.77 - 0.83
6 (1.5 °E - 6 cSt)
11.86
10.2 (10.200 kcal/kg)
0.82 - 0.85
6 (1.5 °E - 6 cSt)
1 (nozzle with return)
0 - 40
60
400/3/50
230/1/50
2800
4500
400
9.1
230 V - 2 x 5 kV
1.9 A - 35 mA
665
7 - 40
140
5500
IP 44
83.9
Tab. A
20033337