4.2.10 Jog operation (Pr. 15, Pr. 16)

Pr. 15 "jog frequency"
Pr. 16 "jog acceleration/deceleration time"
In the external operation mode, jog operation can be started and stopped by the start signal (STF, STR) with
the jog signal ON, after selection of the jog operation function using the input terminal function selection. In
the PU operation mode, jog operation can also be performed using the PU (FR-DU04/FR-PU04).
# Set the frequency and acceleration/deceleration time for jog operation
Parameter
Factory
Number
Setting
15
5Hz
16
0.5 s
Note: 1. In S-shaped acceleration/deceleration pattern A, the set time is a period of time required to reach
Pr. 3 "base frequency".
2. The acceleration time and deceleration time cannot be set separately for jog operation.
3. The value set in Pr. 15 "jog frequency" should be equal to or greater than the Pr. 13 "starting
frequency" setting.
Setting Range
0 to 120Hz
0 to 3600 s
0 to 360 s
Output frequency (Hz)
Pr.20
Jog frequency
Pr.15
setting range
Pr.16
JOG signal
Forward rotation STF
Reverse rotation STR
Related parameters
Pr. 20 "acceleration/deceleration
reference frequency"
Pr. 21 "acceleration/deceleration time
increments"
Pr. 79 "operation mode selection"
Pr. 180 to Pr. 186
(input terminal function selection)
Remarks
When Pr. 21 = 0
When Pr. 21 = 1
Forward
rotation
Reverse
rotation
ON
ON
ON
77
PARAMETERS
Time
4