Chapter 4
Troubleshooting Procedures
Activity T1: Testing
LEDs
Activity T2: Testing
the Hardware
Activity T3: At the
Monitor Prompt
4-8
Remote Annex 6300 Hardware Installation Guide

Table 4-4. Normal Mode Error LED States

Activity
T1: Testing LEDs
T2: Testing Hardware
T3: At Monitor Prompt
Key:
On continuously.
Off.
Flashing irregularly.
Flashing regularly (about 1Hz).
All front panel LEDs light for a few seconds, then all but the Ethernet
Link LED turns off. This sequence confirms that all LEDs are
operational. At this point, the Remote Annex 6300 is in Normal mode.
Press the
button to put the Remote Annex 6300 into ROM
Reset
monitor mode.
During power-up, the Remote Annex 6300 runs self-tests that execute
diagnostics for the CPU, ROM, EEPROM, Flash, etc. The TRAF LED
flashes during the tests and after completing the power-up self-tests,
the STAT and Ethernet Link LED remain on.
When the STAT and ATTN LEDs are on, the ROM monitor prompt
displays on the console terminal. Enter the boot command at the prompt.
If you do not enter a filename with the command, you are prompted to
do so.
STAT
ATTN
Green
Amber
TRAF
Green