Chapter 4
Troubleshooting Procedures
Activity N2: Testing
the Hardware
Activity NE2:
Hardware Failure
4-6
Remote Annex 6300 Hardware Installation Guide
During the power-up sequence, the Remote Annex 6300 runs a series
of self-test diagnostics. These diagnostics test internal hardware
functions. If a test fails, the ATTN and STAT LEDs flash and an error
message is displayed on the console port. The Ethernet LED (Link
LED) lights for a few seconds, then the TRAF LED flashes during the
power-up self-tests. After the self-tests complete, only the STAT and
Ethernet Link LED remain on.
Normal Mode Error Sequence
Table 4-3
shows the state of the LEDs when an error occurs at various
stages of the start-up process. If the Remote Annex 6300 fails during
the hardware-test state (N2), the error condition is hardware failure
NE2. A description of possible causes and solutions for each error
condition is in the following paragraphs.

Table 4-3. Normal Mode Error LED States

Activity
NE2: Hardware Failure
NE5: Booted wrong image
Key:
On continuously.
Off.
Flashing irregularly.
Flashing regularly (about 1Hz).
The ROM diagnostics detected a Remote Annex 6300 hardware
problem requiring service; call Technical Support.
STAT
ATTN
Green
Amber
TRAF
Green