166 Appendix B Using serial PPP

Setting up a Dial-Up Networking connection

To establish a Serial PPP connection using a Microsoft Dial-Up Networking
connection from the client system:
1
2
3
4
5
6
7
8
9
10 Do not configure Scripting and Multilink.
11 Click Configure the client modem, and use the following settings:
NN46110-602
Double-click My Computer.
Double-click the Microsoft Dial-Up Networking icon.
Set the COM port baud rate on the client system so that it is compatible with
the VPN Router's baud rate. It is best to set the rates the same to establish a
connection. Possible rates are:
9600 (default)
19200
38400
56000
Go to Server Types, and under Type of Dial-Up Server, select PPP:
Internet, Windows NT Server, Windows 95. Make sure that none of the
Advanced options are set.
Go to Allowed network protocols, and select TCP/IP.
Go to TCP/IP Settings, and specify your IP address. This is the Management
IP address that the VPN Router uses to communicate with the client that is
dialing in through the modem.
Click Server Assigned name server addresses.
Unclick IP header compression.
Click Use default gateway on remote network.
8 data bits
1 stop bit
No parity
Hardware flow control
Do not choose Log On to Network if the selection appears.