Nortel Circuit Card 311 Reference page 406

Circuit card
Table of Contents

Advertisement

406 NT6D80 MSDL card
Cable installation
When the MSDL card is installed, connect the cables to the equipment
required for the selected operation.
PRI trunk connections
D-channel operations require connections between the MSDL and a PRI
trunk card. Refer to ISDN Primary Rate Interface: Features (NN43001-569)
for a complete discussion of PRI and D-channels.
Procedure 18
Cabling the MSDL card to the PRI card
Step
The following steps explain the procedure for cable connection:
1
2
3
4
5
6
7
I/O panel connections
Operations aside from PRI require cable connections to the I/O panel.
Procedure 19
Cabling the MSDL card to the I/O panel
Step
The following steps explain the procedure for cable connection:
1
2
Copyright © 2003-2008, Nortel Networks
.
Action
Identify the MSDL and the PRI cards to be linked.
Select the appropriate length cable for the distance between the
MSDL and the PRI card.
Plug the 26-pin SCSI II male connector end of a cable into the
appropriate MSDL port.
Route the cable through cable troughs, if necessary, to the
appropriate PRI card.
Plug the DB15 male connector end of the cable into the J5 DB15
female connector on the PRI card.
Secure the connections in place with their fasteners.
Repeat steps 1 through 6 for each connection.
Action
Identify the MSDL card and the I/O panel connector to be linked.
Using the NTND27AB cable, plug the 26-pin SCSI II male connector
end of a cable into the appropriate MSDL port.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
—End—

Advertisement

Table of Contents
loading

This manual is also suitable for:

1000 con?guration guide

Table of Contents