Nortel Circuit Card 311 Reference page 796

Circuit card
Table of Contents

Advertisement

796 NT8D15 E and M Trunk card
The TRC and NTC COS options determine the operation of the switchable
pads contained in the trunk circuits. They are assigned as follows:
Table 309 "Insertion Loss from IPE Ports to IPE Ports (measured in dB)"
(page 796)
Table 309
Insertion Loss from IPE Ports to IPE Ports (measured in dB)
The transmission properties of each trunk are characterized by
class-of-service (COS) assignments in the trunk data block (LD 14). The
assignment may be non-Via Net Loss (non-VNL) or via Net Loss (VNL). To
ensure stability and minimize echo when connecting to long-haul VNL (Tie)
trunks, non-VNL trunks are assigned either Transmission Compensated
(TRC) or Non-Transmission Compensated (NTC) class-of-service.
Copyright © 2003-2008, Nortel Networks
.
TRC for a two-wire non-VNL trunk facility with a loss of greater than 2
dB or for which impedance compensation is provided, or for a four-wire
non-VNL facility.
NTC for a two-wire non-VNL trunk facility with a loss of less than 2 dB or
when impedance compensation is not provided.
shows the insertion loss from IPE port to IPE port.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008