232 NT5D11 and NT5D14 Lineside T1 Interface cards
Command
Description
A E
Alarm Enable
Enables all alarms.
C A
Clear Alarm
Clears all alarms, terminates line processing, and resets the T1 bit error rate
and frame slip counters.
C A L
Clear Alarm Log
Clears the alarm log.
C E
Clear Error
Clears the error counter for the T1.
D A [P]
Display Alarms [Pause]
Displays the alarm log – a list of the most recent 100 alarms along with time
and date stamps.
D C
Display Configuration
Displays the configuration settings for the cards including:
D H [P]
Display History [Pause]
Displays performance counters for the past 24 hours.
D P
Display Performance
Displays performance counters for the current hour.
D S [P]
Display Status [Pause]
Displays carrier status, including whether the card is in the alarm state, and
what alarm level is currently active.
H or ?
Help
Displays the help screen.
L
Login
Logs into the MMI terminal when the system has one Lineside T1 card.
Q
Quit
Logs the terminal user out. If multiple Lineside T1 cards share a single terminal,
logout after using the MMI. Because of the shared daisy-chained link, if a
Lineside T1 card is logged in, it occupies the bus and no other Lineside T1
cards are able to notify the MMI of alarms.
Copyright © 2003-2008, Nortel Networks
.
the serial number of the card
MMI firmware version
date and time
alarm enable/disable setting
self-clearing enable/disable setting
settings entered in Set Configuration
dip switch settings
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard