Menu 30 - Test Options

Option 31 - Walk Test

Menu option 31 allows a selection of zones or a single zone to be put on walk test.
NOTE: Zones programmed with the following functions remain active during the walk test:
24 hours, PA, PA silent, Fire, Tamper, Batt Fail, AC Fail, Assistance, Bell Fail.
Menu Option 31 has two settings:
1 = Test All Zones
This option initiates a walk test that includes all zones that have the omit attribute enabled (refer to option 52 =
PROGRAM ZONES). When selected, the walk test starts immediately. The message NO ENTRIES is
displayed if all zones are non-omittable when selecting All Zones. Non-omittable zones are not included in this
test and remain active throughout the test.
2 = Selected Zones
The scroll keys will scroll between zones. The # key will enable the displayed zone to be put into walk test.
Pressing ent will start the walk test for all zones that have been enabled. The esc key will stop the walk test
and return to the menu.
Where RF zones are being walk tested, the system places all receivers into "Reduced Gain mode". The
received signal strength is displayed for V2 peripherals when the zone is tested. 5800 series detectors will not
give that signal strength.

Option 32 - Output Test

Menu option 32 allows each of the output function types to be scrolled through and toggled on/off by pressing
the ent key. If a user has activated the output test, they can only turn on the bells and strobe. No other output
types can be selected by the user. Refer to 53 = Outputs for a full description of each output function.