Galaxy 2 Series Installation Manual
Parameter
01=Bell Time
01-30 minutes (1 minute intervals - defaults to 15)
02=Bell Delay
0=Off. 1=On - 10 min.
04=Exit Time
00 - 99 Seconds. 00=Infinite time/final contact.
05=Entry Time
00 - 99 seconds.
06=Part set exit
0=Silent 1=Keypad only 2=Keypad & Speaker
07=Intruder Resets
0=User 1=Remote
08=Exit Terminate
0=No 1=Full set only 2=Full and part set only 3=All set modes
09=Zone lockout
Alarms per set period, 0-9 Events
10=Horn Volume
00-31
11=Audible power fault
0=No 1=Yes (AC fail after 1 hour, Batt low immediate)
1=Top Line
2=Bottom Line programmed as for SMS
12=Banner
3=Show on Set
1=Mode (0=Off, 1=On, 2=On+ Keyfob panic)
13=Hot keys
2=Audible Panic (0=No, 1=Yes)
14=Lockouts
0=Off 1=Keypad 2=Fob and Tag 3=All
15=SPK Mode
LS Output 0 = Switch DC 1 = Speaker Driver
Selects access authorization required
16=Master Code
1=Always authorized 2=Temp authorized (via menu 48)
1=Enter performs a reboot, After warning.
17=Restart
2=Enter loads the factory default programming.
Sub options selectable. Each is stop set on/off
18=Stop Set
1=AC Fail, 2=Batt fault, 3=RF Jam, 4=Tel Line fault
19=Part Bells
0=No 1=Yes
20=Night Bells
0=No 1=Yes
21=Reset Manager
Enter to reset manager code to default, after warning
1=Mode: 0=Off, 1=On (In parallel to other resets)
22=Technistore
2=Version (000-255)
23=Alerts
1=Audible and visible 2=Audible only 3=Visible only
24=Entry Deviation
0=No 1=Yes (Default for EN50131-1)
25=Easy set
0=No 1=Yes
26=Sup. Entry
0=No 1=Yes
3 Sub options:
1=Zone config, 0=NC, 1=Double Balance, 2=EOL
46=Zone resistance
2=EOL resistor, (1 - 99) X 100 Ohms, 100 ohm intervals
3=Contact Res, (1 - 99) X 100 Ohms, 100 ohm intervals
47=Set confirm
0=Off 1=Strobe (for 2 seconds). 2=Strobe and Bell (for 2 seconds when set terminates).
50=RF Options
1=RF Fob unset: 0=Disable fobs, 1=Unset anytime, 2=After Entry.
2=Supervision (0=2.0 hrs, 1=3.6 hrs, 2=8.4 hrs)
3=Audible Jam
4=Audible Supervision
5=Audible RF Low Bat
For 3, 4, 5
6 = RF Check
55=DD243
1=Confirm Time
2=Confirm Mode
3=Restrict Keypad
4=Restart Time
5=Reduced Resets.
6=Re-arm mode
7=Entry T/O Conf.
8=Exit ZN conf.
9=Entry clears conf.
Values
0=Off (Blank display when set)
1=On (Display normal banner when set)
0=No
1=Yes
0=No
1=Yes
(00-60) minutes, 0=Full set period
0=Disabled
1=Before Entry (No portable ACE)
2=Except Entry (With portable ACE)
3=Always Confirm (Non DD243)
0=No
1=During Entry Period
2=Never Unset
0=No
1=If first Zn Repeats
0=Off
1=On Unconfirmed
0=On Confirm
1=On Bell Timeout
0=No
1=Yes
0=Before Entry
1=Except entry
0=Reset Count
1=Keep Count
Table 18. System Parameters
51 - Parameters (cont'd)
59
Defaults
15 minutes
0 = Off
30
30
1 = Keypad
1 = Remote
0 = No
0 = No Lockout
10
1 = Yes
Blank
Blank
1 = On
0 = Off
0 = No
3 = All
1 = SPK Driver
1 = Always
-
All 1 = On
1 = Yes
1 = Yes
-
0 = Off
1 = Aud & Vis
1 = Yes
0 = No
0 = No
1 = Doub Bal
10 (1000)
10 (1000)
0 = Off
1 = Anytime
0 = 2 hrs
0 = No
1 = Yes
30
2 = Except Entry
0 = No
0 = No
1 = On Unconfirmed
0 = On Conf.
0 = No
0 = Before Entry
1 = Keep Count