51 - Parameters (cont'd)
01 = Bell Time
This is the amount of time that the sounders/bells activate after an alarm condition has occured. The duration
of the output is programmable within the range 1-30 minutes; the default is 15. Assigning a value of 00 sets the
Bell Time to one hour maximum.
02 = Bell Delay
This parameter, when set to On, delays the operation of the bell for 10 minutes following an intruder alarm.
04 = Exit time
This is the amount of time that the user has to exit the premises after initiating a Full Set procedure. The Exit
Time is programmable within the range 00 - 99 seconds. If Final Contact is required then enter 00. The
system will only set when a final exit zone is activated after the exit timer has started (infinite exit time).
This parameter can be assigned a different value for each group, when groups are enabled.
05 = Entry Time
This is the amount of time that the user has to enter the premises and Unset the system. The Entry Time is
programmable within the range 00 - 99 seconds. The Entry Time is initiated by opening a zone programmed as
Final Exit. Assigning a value of 00 seconds sets the entry time to infinity.
This parameter can be assigned a different value for each group, when groups are enabled.
06 = Part Set Exit
This parameter allows the Part Set exit timer to be silent, audible through the keypad, or, audible through the
keypad and internal sounder. Night Set will always have a silent exit timer but this option will affect the Night
Set comfort tone (confirmation of set) and fault warnings given at the end of the Exit Time. All possible options
are shown in the following three tables.
Part Set
Night Set
Part Set
Night Set
P ART SET EXIT W ARNING – 51 06 2 KEYP AD BUZZER AND INTERN AL SOUNDER
Part Set
Night Set
P ART SET EXIT W ARNING – 51 06 0 SILENT
EXIT TONE
None
None
Table 19. Part Set Exit W arning - Silent
P ART SET EXIT W ARNING – 51 06 1 KEYP AD BUZZER ONLY
EXIT TONE
Keypad only
None
Table 20. Part Set Exit W arning – Buzzer O nly
EXIT TONE
Both
None
Table 21. Part Set Exit W arning – Buzzer & Internal sounder
Galaxy 2 Series Installation Manual
FAULT TONE
FAULT TONE
AT END OF
EXIT TIME
None
Keypad only
None
Keypad only
FAULT TONE
FAULT TONE
AT END OF
EXIT TIME
Keypad only
Keypad only
None
Keypad only
FAULT TONE
FAULT TONE
AT END OF
EXIT TIME
Both
Both
None
Both
60
COMFORT
TONE
Keypad only
Keypad only
COMFORT
TONE
Keypad only
Keypad only
COMFORT
TONE
Both
Both