52 - Zones (cont'd)
5 = RF Options
These options allow the zone to be set up with a wireless detector.
There are six options selectable with this attribute:
1. Serial number
This allows the detector's unique serial number to be entered by typing the number or by using the auto-learn
function. To use the auto-learn, activate the detector's tamper switch. On learning, the signal strength is dis-
played.
2. Loop number
On 5800 series detectors, this selects the loop input to be used on this zone.
3. Supervision
This enables or disables supervision of the wireless detector.
4. Auto reset
The Auto reset function can be enabled to force the zone to automatically close after five seconds, if no close
signal is received from the transmitter. This will be useful on certain installations.
5. Last signal
This shows the strength of the last signal received from this detector for V2 peripherals; 5800 series detectors
will not show that signal strength.
6. Lowest signal
Lowest Signal will show the lowest signal strength received from that device since records were reset in menu
61. This is for V2 peripherals only; 5800 series detectors will not show this signal strength.
NOTE: If two receivers are fitted, both signals will be shown. If only one receiver is fitted, the reading for
that receiver only will be shown. The receiver not fitted will show a reading of 0, eg. 9/0.
6 = Groups
This option selects the group that a zone belongs to. The zone will always default to group 1, but can be set to
work under any group.
01 Final
Zones programmed as Final initiate the unsetting procedure and terminate the setting procedure.
NOTE: The setting procedure can only terminate if the Exit Time (Parameter 51.04) is set to zero.
Opening the Final zone when the system or group is set starts the entry timer; opening and then closing the
Final zone during the exit procedure sets the system or assigned groups, providing all the zones are closed.
The opening (+) and closing (–) of Final zones during the setting and unsetting procedures are recorded in the
event log.
Pressing the
key when programming a Final zone doubles the entry time of the group.
Opening a Final zone during the exit time is not reported on the keypad as an open zone; the Entry/Exit
Horns bleep rapidly to indicate that the zone is open.